Adaptation of the doubly labeled water method for subjects consuming isotopically enriched water.

نویسندگان

  • R J Gretebeck
  • D A Schoeller
  • R A Socki
  • J Davis-Street
  • E K Gibson
  • L O Schulz
  • H W Lane
چکیده

The use of doubly labeled water (DLW) to measure energy expenditure is subject to error if the background abundance of the oxygen and hydrogen isotope tracers changes during the test period. This study evaluated the accuracy and precision of different methods by which such background isotope changes can be corrected, including a modified method that allows prediction of the baseline that would be achieved if subjects were to consume water from a given source indefinitely. Subjects in this study were eight women (4 test subjects and 4 control subjects) who consumed for 28 days water enriched to resemble drinking water aboard the United States space shuttle. Test subjects and control subjects were given a DLW dose on days 1 and 15, respectively. The change to an enriched water source produced a bias in expenditure calculations that exceeded 2.9 MJ/day (35%), relative to calculations from intake-balance. The proposed correction based on the predicted final abundance of 18O and deuterium after equilibration to the new water source eliminated this bias, as did the traditional use of a control group. This new modified correction method is advantageous under field conditions when subject numbers are limited.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stable isotope ratio measurements on highly enriched water samples by means of laser spectrometry.

We demonstrate the feasibility of using laser spectrometry (LS) to analyze isotopically highly enriched water samples (i.e., delta2H < or = 15,000/1,000, 18O < or = 1,200/1,000), as often used in the biomedical doubly labeled water (DLW) method to quantify energy metabolism. The method is an important extension of a recently developed infrared laser direct absorption spectrometer. The measureme...

متن کامل

Natural abundance deuterium and 18-oxygen effects on the precision of the doubly labeled water method.

The doubly labeled water method for measuring total energy expenditure is subject to error from natural variations in the background 2H and 18O in body water. There is disagreement as to whether the variations in background abundances of the two stable isotopes covary and what relative doses of 2H and 18O minimize the impact of variation on the precision of the method. We have performed two stu...

متن کامل

Application of the Doubiy Labeied Water Technique for Studying Total Energy Expenditure in Young Chiidren: A Review

The doubly labeled water tecbnique represents an unobtrusive and noninvasive means lo measure total daily energy expenditure in free-living human subjects who are unaware that energy expenditure is being measured. When combined with measurement of resting energy expenditure, the doubly labeled water technique can also be used to estimate energy expenditure related to physical activity. The rela...

متن کامل

Validity of the Modified Baecke Questionnaire: comparison with energy expenditure according to the doubly labeled water method

BACKGROUND In epidemiological research, physical activity is usually assessed by questionnaires. Questionnaires are suitable for large study populations since they are relatively inexpensive and not very time consuming. However, questionnaire information is by definition subjective and prone to recall bias, especially among elderly subjects. The Modified Baecke Questionnaire, developed by Voorr...

متن کامل

Energy expenditure by doubly labeled water: validation in humans and proposed calculation.

To further validate the doubly labeled water method for measurement of CO2 production and energy expenditure in humans, we compared it with near-continuous respiratory gas exchange in nine healthy young adult males. Subjects were housed in a respiratory chamber for 4 days. Each received 2H2(18)O at either a low (n = 6) or a moderate (n = 3) isotope dose. Low and moderate doses produced initial ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of applied physiology

دوره 82 2  شماره 

صفحات  -

تاریخ انتشار 1997