Application of factorial design and Doehlert matrix for determination of trace lead in environmental samples by on-line column preconcentration FAAS using silica gel chemically modified with niobium(V) oxide.

نویسندگان

  • Kalya Cravo Di Pietro Roux
  • Heloisa França Maltez
  • Jeferson Schneider Carletto
  • Edmar Martendal
  • Eduardo Carasek
چکیده

In this study a new method for Pb determination in water using solid phase extraction coupled to a flow injection system and flame atomic absorption spectrometry was developed. The sorbent used for Pb preconcentration and extraction was silica gel chemically modified with niobium(V) oxide. Flow and chemical variables of the system were optimized through a multivariate procedure. The factors selected were buffer type, eluent concentration, and sample and eluent flow rates. It was verified that the aforementioned factors as well as their interactions were statistically significant at the 95% confidence level. The effect of foreign ions was evaluated using a fractionary factorial experimental design. The detection limit was 0.35 microg L(-1) and the precision was 1.6%. Results for recovery tests using different environmental samples were between 90 and 104%. Certified reference materials were analyzed in order to check the accuracy of the proposed method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preconcentration of Pb(II) by Graphene Oxide with Covalently Linked Porphyrin Adsorbed on Surfactant Coated C18 before Determination by FAAS

A simple, highly sensitive, accurate and selective method for determination of trace amounts of Pb(II) in water samples is presented. A novel Graphene oxide with covalently linked porphyrin solid-phase extraction adsorbent was synthesized by covalently linked porphyrin onto the surfaces of graphite oxides. The stability of a chemically (GO-H2P) especially in concentrated hydrochloric acid was s...

متن کامل

Preconcentration of Pb(II) by Graphene Oxide with Covalently Linked Porphyrin Adsorbed on Surfactant Coated C18 before Determination by FAAS

A simple, highly sensitive, accurate and selective method for determination of trace amounts of Pb(II) in water samples is presented. A novel Graphene oxide with covalently linked porphyrin solid-phase extraction adsorbent was synthesized by covalently linked porphyrin onto the surfaces of graphite oxides. The stability of a chemically (GO-H2P) especially in concentrated hydrochloric acid was s...

متن کامل

Use of factorial design and Doehlert matrix for multivariate optimisation of an on-line preconcentration system for lead determination by flame atomic absorption spectrometry.

A system for on-line preconcentration and determination of lead by flame atomic absorption spectrometry (FAAS) was proposed. It was based on the sorption of lead(II) ions on a minicolumn of polyurethane foam loaded with 2-(2-thiazolylazo)-5-dimethylaminophenol (TAM). The optimisation step was carried out using two-level full factorial and Doehlert designs for the determination of the optimum co...

متن کامل

Extraction sorbent with octadecane-functionalized nano graphene for the preconcentration of Cu(II) in water and tissues from liver loggerhead turtles specimens

A simple, highly sensitive, accurate and selective method for determination of trace amounts of Cu2+ in water samples was reported. In this paper, Isopropyl 2-[(isopropoxy carbothioyl)disulfanyl]ethanethioate (IIDE) in order to prepare an effective sorbent for the preconcentration and determination of Cu. The sorption capacity of Isopropyl 2-[(isopropoxy carbothioyl)disulfanyl]ethanethioate (II...

متن کامل

Extraction sorbent with octadecane-functionalized nano graphene for the preconcentration of Cu(II) in water and tissues from liver loggerhead turtles specimens

A simple, highly sensitive, accurate and selective method for determination of trace amounts of Cu2+ in water samples was reported. In this paper, Isopropyl 2-[(isopropoxy carbothioyl)disulfanyl]ethanethioate (IIDE) in order to prepare an effective sorbent for the preconcentration and determination of Cu. The sorption capacity of Isopropyl 2-[(isopropoxy carbothioyl)disulfanyl]ethanethioate (II...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 24 3  شماره 

صفحات  -

تاریخ انتشار 2008