Should forced expiratory volume in six seconds replace forced vital capacity to detect airway obstruction?
نویسندگان
چکیده
It has been suggested that forced expiratory volume in six seconds (FEV(6)) should be substituted for forced vital capacity (FVC) to measure fractions of timed expired volume for airflow obstruction detection. The present authors hypothesised that this recommendation might be questionable because flow after 6 s of forced expiration from more diseased lung units with the longest time constants was most meaningful and should not be ignored. Furthermore, previous studies comparing FEV(6) and FVC included few subjects with mild or no disease. The present study used spirometric data from the USA Third National Health and Nutrition Evaluation Survey with prior published ethnicity- and sex-specific equations for FEV(1)/FEV(6), FEV(1)/FVC and FEV(3)/FVC, and new equations for FEV(3)/FEV(6), all derived from approximately 4,000 adult never-smokers aged 20-80 yrs. At 95% confidence intervals, 21.3% of 3,515 smokers and 41.3% of smokers aged >51 yrs had airway obstruction; when comparing FEV(1)/FEV(6) with FEV(1)/FVC, 13.5% were concurrently abnormal, 1.5% were false positives and 4.1% were false negatives; and when comparing FEV(3)/FEV(6) with FEV(3)/FVC, 11.6% were concurrently abnormal, 3.3% were false positives and 5.7% were false negatives. Substituting forced expiratory volume in six seconds for forced vital capacity to determine the fractional rates of exhaled volumes reduces the sensitivity of spirometry to detect airflow obstruction, especially in older individuals and those with lesser obstruction.
منابع مشابه
[Airflow limitation in Brazilian Caucasians: FEV1/FEV6 vs. FEV1/FVC].
OBJECTIVE To evaluate the use of the forced expiratory volume in one second/forced expiratory volume in six seconds (FEV1/FEV6) ratio as an alternative to the FEV1/forced vital capacity (FVC) ratio in the detection of mild airway obstruction. METHODS Reference equations for the Brazilian population in 2006 were used in order to determine the lower limits of normality for the FEV1/FEV6 and FEV...
متن کاملEpidemiology and costs of COPD.
1 Hansen JE, Sun X-G, Wasserman K. Should forced expiratory volume in six seconds replace forced vital capacity to detect airway obstruction? Eur Respir J 2006; 27: 1244–1250. 2 Hansen JE, Sun XG, Wasserman K. Discriminating measures and normal values for expiratory obstruction. Chest 2006; 129: 369–377. 3 Enright P. Does screening for COPD by primary care physicians have potential to cause mor...
متن کاملObstructive and restrictive spirometric patterns: fixed cut-offs for FEV1/FEV6 and FEV6.
The purpose of this study was to determine fixed cut-off points for forced expiratory volume in one second (FEV(1))/FEV(6) and FEV(6) as an alternative for FEV(1)/forced vital capacity (FVC) and FVC in the detection of obstructive and restrictive spirometric patterns, respectively. For the study, a total of 11,676 spirometric examinations, which took place on Caucasian subjects aged between 20-...
متن کاملCut-off value of FEV1/FEV6 as a surrogate for FEV1/FVC for detecting airway obstruction in a Korean population
BACKGROUND Forced expiratory volume in 1 second (FEV1)/forced expiratory volume in 6 seconds (FEV6) has been proposed as an alternative to FEV1/forced vital capacity (FVC) for detecting airway obstruction. A fixed cut-off value for FEV1/FEV6 in a Korean population is lacking. We investigated a fixed cut-off for FEV1/FEV6 as a surrogate for FEV1/FVC for detecting airway obstruction. MATERIALS ...
متن کاملDependence of forced vital capacity manoeuvre on time course of preceding inspiration in patients with restrictive lung disease.
In normal subjects and patients with airway obstruction, flows during a forced vital capacity (FVC) manoeuvre are higher after a fast inspiration without an end-inspiratory pause (manoeuvre 1) as compared to a slow inspiration with an end-expiratory pause of approximately 5 s (manoeuvre 2). In this study, we investigated the influence of these manoeuvres on maximal expiratory volume-time and fl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The European respiratory journal
دوره 27 6 شماره
صفحات -
تاریخ انتشار 2006