Calibration of Three Dimensional Mechanism - Novel Calibration Method for 3DOF Parallel Mechanism -
نویسنده
چکیده
Many types of three dimensional mechanisms (3Dmechanism) are used in modern industry. Specially, in automation technology, product engineering and robotics, 3D-mechanisms play the key roles of complicated manipulation, 3D positioning and 3D measurement. Usually, the repeatability of 3D-mechanism is tested and evaluated. However, when we use 3D-mechanism in wide purposes and in wide conditions, the absolute calibration is the key technique to control the mechanism precisely. In this article, we analyze theoretically the method of the absolute calibration for 3D-mechanisms, such as a Cartesian mechanism, an articulated mechanism and a parallel mechanism. After theoretical analysis, we introduce a novel 3DOF parallel mechanism for a coordinate measuring machine (CMM) and a micro milling machine and a novel calibration method for these parallel mechanisms.
منابع مشابه
Kinematic Mapping and Forward Kinematic Problem of a 5-DOF (3T2R) Parallel Mechanism with Identical Limb Structures
The main objective of this paper is to study the Euclidean displacement of a 5-DOF parallel mechanism performing three translation and two independent rotations with identical limb structures-recently revealed by performing the type synthesis-in a higher dimensional projective space, rather than relying on classical recipes, such as Cartesian coordinates and Euler angles. In this paper, Study's...
متن کاملImprovement of Accuracy in Environmental Dosimetry by TLD Cards Using Three-dimensional Calibration Method
Background: The angular dependency of response for TLD cards may cause deviation from its true value on the results of environmental dosimetry, since TLDs may be exposed to radiation at different angles of incidence from the surrounding area.Objective: A 3D setting of TLD cards has been calibrated isotropically in a standard radiation field to evaluate the improvement of the accuracy of meas...
متن کاملFull parameter calibration of parallel mechanism
Calibration of a parallel mechanism using a specified artifact, artifact calibration, is an effective method. However, there are strong correlations between each parameter in an artifact calibration of a parallel mechanism. Therefore, it is difficult to identify all kinematic parameters included in a kinematic model of the parallel mechanism from measuring data. In this research, we propose two...
متن کاملKinematic Calibration for Redundantly Actuated Parallel Mechanisms
We present a new kinematic calibration algorithm for redundantly actuated parallel mechanisms, and illustrate the algorithm with a case study of a planar seven-element 2-degree-of-freedom (DOF) mechanism with three actuators. To calibrate a nonredundantly actuated parallel mechanism, one can find actual kinematic parameters by means of geometrical constraint of the mechanism’s kinematic structu...
متن کاملPartial Least Square and Parallel Factor Analysis Methods Applied for Spectrophotometric Determination of Cefixime in Pharmaceutical Formulations and Biological Fluid
In this study, the direct determination of cefixime as an anti-bacterial agent, in pharmaceutical formulations, urine and human blood plasma was conducted based on spectrophotometric measurements using parallel factor analysis (PARAFAC) and partial least squares (PLS). The calibration set was composed of fourteen solutions in the range of 0.50- 9.00 µg mL-1. PLS models were calculated at each p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2002