Effect of two different soft liners and thicknesses mediating stress transfer for immediately loaded 2-implant supported mandibular overdentures: A finite element analysis study.

نویسندگان

  • Iman Abd-Elwahab Radi
  • Nesrin Elmahrouky
چکیده

STATEMENT OF PROBLEM The use of soft liners as female receptacles for ball attachments retaining immediately loaded implant overdenture has been recommended to enhance osseointegration and provide a shock absorbing effect. However, which liner and which thickness is still unclear. PURPOSE The purpose of this finite element analysis (FEA) study was to evaluate the effect of a 2- and 4-mm thickness of thermoplastic resin (TRL) and silicone-based liners (SBL) on the displacement and stresses transmitted to immediately loaded implants retaining a mandibular overdenture. MATERIAL AND METHODS Four 3-dimensional (3D) FEA models of a mandibular implant overdenture retained by 2 ball attachments (2 models for each lining material with 2- or 4-mm liner thicknesses) were developed. Implants were placed in the canine regions and surrounded by a 1-mm cylinder of immature bone simulating immediate loading. A vertical and an oblique load of 150 N were applied in the right premolar molar regions. Stresses and displacement were set as output variables. RESULTS Replacing the TRL by the SBL was associated with a decrease in stresses by 73% and in displacement by at least 46%. Increasing the thickness of any liner decreases stresses by 45% during vertical loading and by 25% during oblique loading and decreases displacement by 61.5% during vertical loading and by an average of 32.5% during oblique loading. None of the liners exceeded the experimental risk limits for micromotion at the bone-implant interface (50 μm). CONCLUSION In immediately loaded mandibular implant overdentures, both SBL and TRL decrease the micromotion of implants and the stresses at the bone-implant interface. However, SBL is more effective. The thickness of both liners seems to play a major role in decreasing the stresses and displacement of periimplant tissues.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Abutment Height Difference on Stress Distribution in Mandibular Overdentures: A Three-Dimensional Finite Element Analysis

Background and Aim: Implant-supported overdentures are a treatment option for edentulous patients. One of the important factors in determining the prognosis of overdenture treatment is to control the distribution of stress in the implant-bone and attachment complex. This study assessed the effect of implant abutment height difference on stress distribution in mandibular overdentures. Materials...

متن کامل

Immediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis

Immediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis Dr. A. Fazel * - Dr. SH. A. Alai ** - Dr. M. Rismanchian *** *Associate Professor of Prosthodontics Dept., Faculty of Dentistry and Dental Research Center, Tehran University / Medical Sciences. **Assistant Professor of Prosthodontics Dept., Faculty of...

متن کامل

تعیین توزیع تنش استخوان اطراف ایمپلنت‌های فک پایین در طرح‎های مختلف پروتز به هنگام Mandibular- Flexure

Statement of Problem: In the treatment of edentulous patients with implant supported fixed partial dentures several factors such as implant numbers, implant position, superstructure pattern and cantilever length must be considered. Mandibular flexture in function exerts forces in peri-implant bone, however this phenomenon has received little attention. Purpose: The goal of this finite element a...

متن کامل

Effect of cantilever length on stress distribution around implants in mandibular overdentures supported by two and three implants

OBJECTIVE There is no definitive study comparing stress distribution around two versus three implants in implant-retained overdentures with different cantilever length. The purpose of this finite element study was to evaluate stress pattern around the implants of the 2 or 3 implant- supported mandibular overdenture with different cantilevered length. MATERIALS AND METHODS The models used in t...

متن کامل

Comparison of the Effect of Ball and Bar Attachment Designs on Retention and Stability of Mandibular Implant-Supported Overdentures

Objectives: The present study evaluated the effect of bar and ball attachment designs on retention and stability of a mandibular overdenture supported by four implants. Methods: An edentulous mandibular acrylic resin model with four implants in the anterior part of the ridge (A, B, D and E) was fabricated. A metal framework simulating the overdenture was also fabricated. Totally, 30...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of prosthetic dentistry

دوره 116 3  شماره 

صفحات  -

تاریخ انتشار 2016