Air supply volumes and velocities in cleanrooms are monitored by airflow measuring hoods and anemometers but these measuring methods can be inaccurate if used incorrectly. It is demonstrated in this article that measuring hoods are accurate if the air supply passes evenly out of the hood, as occurs when the air volume is measured from a four-way diffuser or no air supply diffuser. However, when a swirl diffuser was investigated, the measuring hood gave readings more than 50% greater than the true volume. The reasons for the inaccuracy, and methods to correct it were established. Vane anemometers give inaccurate readings at the face of high-efficiency air supply filters, and it was found that the most accurate reading was found about 15 cm from the filter face. The number of readings required across the filter face to obtain an accurate average velocity was investigated, as was a scanning method using overlapping passes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Decay of airborne contamination and ventilation effectiveness of cleanrooms

This article reports an investigation into the ability of the air supply in non-unidirectional cleanrooms to aid recovery from episodes of airborne contamination, and minimise airborne contamination at important locations. The ISO 14644-3 (2005) recovery test, which measures the rate of decay of test particles, was assessed and a reinterpretation of the test results suggested. This allowed air ...

متن کامل

Calculation of air supply rates and concentrations of airborne contamination in non- UDAF cleanrooms

W Whyte1, T Eaton2, WM Whyte1, N Lenegan3, S Ward4 and K Agricola5 1 School of Engineering, University of Glasgow, Glasgow G12 8QQ 2 AstraZeneca, Macclesfield, Cheshire, SK10 2NA 3 Energy and Carbon Reduction Solutions, Ashton-Under-Lyne, Lancashire, OL5 0RF 4 Validair, Wrotham, Kent, TN15 7RJ 5 Technology of Sense BV, Institutenweg 15, Enschede, 7521PH, the Netherlands Calculation of air suppl...

متن کامل

ارزیابی پارامترهای عملکردی در فیلترهای هپا در یک صنعت دارویی(مطالعه موردی1394)

Abstract: Background and aims: Nowadays, cleanrooms have become impartible parts of an industry with sensitive products. Sources of contamination in cleanrooms are impaired performance and quality sensitive products in the cleanrooms .The aim of this study was to evaluate the efficiency of HEPA filter and check the concentration and number of airborne particles in cleanrooms for pharmaceutic...

متن کامل

Calculation of airborne cleanliness and air supply rate for non-unidirectional airflow cleanrooms

When designing a cleanroom to achieve a required airborne cleanliness standard or grade, such as specified in ISO 1464411 or the European Union Guidelines to Good Manufacturing Practice (EU GGMP)2, designers have difficulties deciding how much filtered air should be supplied to the cleanroom to achieve the correct airborne cleanliness requirement. Currently, this decision is based on experience...

متن کامل

Effect of ventilation air velocities on diesel particulate matter dispersion in underground coal mines

This paper presents a detailed account of computational fluid dynamics (CFD) simulations undertaken to investigate the influence of intake (ventilation) air velocities on the flow patterns of diesel particulate matter (DPM) generated by a man-riding vehicle operating in a straight rectangular cross section tunnel in an underground coal mine. The simulation results are validated against an earli...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014