Magnetic resonance imaging of the Amine-Proton EXchange (APEX) dependent contrast
نویسندگان
چکیده
Chemical exchange between water and labile protons from amino-acids, proteins and other molecules can be exploited to provide tissue contrast with magnetic resonance imaging (MRI) techniques. Using an off-resonance Spin-Locking (SL) scheme for signal preparation is advantageous because the image contrast can be tuned to specific exchange rates by adjusting SL pulse parameters. While the amide-proton transfer (APT) contrast is obtained optimally with steady-state preparation, using a low power and long irradiation pulse, image contrast from the faster amine-water proton exchange (APEX) is optimized in the transient state with a higher power and a shorter SL pulse. Our phantom experiments show that the APEX contrast is sensitive to protein and amino acid concentration, as well as pH. In vivo 9.4-T SL MRI data of rat brains with irradiation parameters optimized to slow exchange rates have a sharp peak at 3.5 ppm and also broad peak at -2 to -5 ppm, inducing negative contrast in APT-weighted images, while the APEX image has large positive signal resulting from a weighted summation of many different amine-groups. Brain ischemia induced by cardiac arrest decreases pure APT signal from ~1.7% to ~0%, and increases the APEX signal from ~8% to ~16%. In the middle cerebral artery occlusion (MCAO) model, the APEX signal shows different spatial and temporal patterns with large inter-animal variations compared to APT and water diffusion maps. Because of the similarity between the chemical exchange saturation transfer (CEST) and SL techniques, APEX contrast can also be obtained by a CEST approach using similar irradiation parameters. APEX may provide useful information for many diseases involving a change in levels of proteins, peptides, amino-acids, or pH, and may serve as a sensitive neuroimaging biomarker.
منابع مشابه
Sensitivity and source of amine-proton exchange and amide-proton transfer magnetic resonance imaging in cerebral ischemia.
PURPOSE Amide-proton transfer (APT) and amine-water proton exchange (APEX) MRI can be viable to map pH-decreasing ischemic regions. However, their exact contributions are unclear. METHODS We measured APEX- and APT-weighted magnetization transfer ratio asymmetry (denoted as APEXw and APTw), apparent diffusion coefficient, T2 , and T1 images and localized proton spectra in rats with permanent m...
متن کاملAnalytical determination of the chemical exchange saturation transfer (CEST) contrast in molecular magnetic resonance imaging
Magnetic resonance based on molecular imaging allows tracing contrast agents thereby facilitating early diagnosis of diseases in a non-invasive fashion that enhances the soft tissue with high spatial resolution. Recently, the exchange of protons between the contrast agent and water, known as the chemical exchange saturation transfer (CEST) effect, has been measured by applying a suitable pulse ...
متن کاملSynthesis and biological evaluation of a novel Glucosylated Derivative of Gadolinium Diethylenetriaminepentaacetic acid for Tumor Magnetic Resonance Imaging
Cancer detection in early stage using a powerful and noninvasive tool is of high global interest. In this experiment, a small-molecular-weight glucose based derivative of Gd3+-1-(4-isothiocyanatobenzyl) diethylene tri amine penta acetic acid (Gd3+-p-SCN-Bn‐DTPA‐DG) as a novel potential MR imaging contrast agents was synthesized. Gd3+-p-SCN-Bn‐DTPA‐DG was synthesized with reacting of Glucosamine...
متن کاملSynthesis and biological evaluation of a novel Glucosylated Derivative of Gadolinium Diethylenetriaminepentaacetic acid for Tumor Magnetic Resonance Imaging
Cancer detection in early stage using a powerful and noninvasive tool is of high global interest. In this experiment, a small-molecular-weight glucose based derivative of Gd3+-1-(4-isothiocyanatobenzyl) diethylene tri amine penta acetic acid (Gd3+-p-SCN-Bn‐DTPA‐DG) as a novel potential MR imaging contrast agents was synthesized. Gd3+-p-SCN-Bn‐DTPA‐DG was synthesized with reacting of Glucosamine...
متن کاملANALYTICAL STUDY OF EFFECT OF BILAYER INORGANIC AND ORGANIC COATING AROUND THE IRON OXIDE NANOPARTICLES ON MAGNETIC RESONANCE IMAGING CONTRAST
Background & Aims: In recent years, iron oxide nanoparticles have been used in contrast-enhanced magnetic resonance imaging for diagnosing a wide range of diseases. In order to provide biocompatibility and prevent the toxicity of the nanoparticles, using organic or inorganic coating around these nanoparticles is important for their application. The aim of this study is to investigate the effect...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- NeuroImage
دوره 59 2 شماره
صفحات -
تاریخ انتشار 2012