Spin echo without an external permanent magnetic field

نویسندگان

  • Joakim Bergli
  • Leonid Glazman
چکیده

We suggest a sequence of instantaneous spin rotations, that reverses the time evolution of a spin subject to an arbitrary built-in magnetic field. The sequence does not require the knowledge of the direction or strength of the built-in field, and is applicable as long as that field is constant in time. The advantage of the suggested sequence compared to the known spin-echo sequences is that it does not involve the application of a permanent strong magnetic field. The spin rotations may be achieved by application of short magnetic field pulses.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thermal negativity in a two qubit XXX and XX spin chain model in an external magnetic field

In this paper we studied the thermal negativity in a two-qubit XX spin ½ chain model and XXX spin1/2 chain model(isotropic Heisenberg model)spin-1/2 chain subjected to an external magnetic field inz direction. We calculate analytical relation for the thermal negativity for two qubit XX and XXX spinchain models in the external magnetic field. Effects of the magnetic field and temperature on then...

متن کامل

Entanglement in the XZ spin chain model in the external magnetic field

The entanglement at zero-temperature is studied in a two-qubit XZ spin-1/2 chain model in anexternal magnetic field which is applied in the z direction. We have obtained an analytical relation forthe effect of the external magnetic field on the concurrence. It is shown that the ground state of thesystem depends on the strength of exchange coupling. We have shown that the analytical relation oft...

متن کامل

اندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی

Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...

متن کامل

High resolution NMR imaging using a high field yokeless permanent magnet.

We measured the homogeneity and stability of the magnetic field of a high field (about 1.04 tesla) yokeless permanent magnet with 40-mm gap for high resolution nuclear magnetic resonance (NMR) imaging. Homogeneity was evaluated using a 3-dimensional (3D) lattice phantom and 3D spin-echo imaging sequences. In the central sphere (20-mm diameter), peak-to-peak magnetic field inhomogeneity was abou...

متن کامل

Geometric distortion evaluation of magnetic resonance images by a new large field of view phantom for magnetic resonance based radiotherapy purposes

Background: The magnetic resonance imaging (MRI)-based radiotherapy planning method have been considered in recent years because of the advantages of MRI and the problems of planning with two images modality. The first step in MRI-based radiotherapy is to evaluate magnetic resonance (MR) images geometric distortion. Therefore, the present study aimed to evaluate system related geometric distort...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007