Distortion Product Otoacoustic Emissions and Intracranial Pressure During CSF Infusion Testing.

نویسندگان

  • Michael A Williams
  • Jan Malm
  • Anders Eklund
  • Nicholas J Horton
  • Susan E Voss
چکیده

BACKGROUND A noninvasive method to monitor changes in intracranial pressure (ICP) is required for astronauts on long-duration spaceflight who are at risk of developing the Visual Impairment/Intracranial Pressure syndrome that has some, but not all of the features of idiopathic intracranial hypertension. We assessed the validity of distortion product otoacoustic emissions (DPOAEs) to detect changes in ICP. METHODS Subjects were eight patients undergoing medically necessary diagnostic cerebrospinal fluid (CSF) infusion testing for hydrocephalus. DPOAE measurements were obtained with an FDA-approved system at baseline and six controlled ICP levels in ∼3 mmHg increments in random order, with a range from 10.8 ± 2.9 mmHg (SD) at baseline to 32.3 ± 4.1 mmHg (SD) at level 6. RESULTS For f2 frequencies between 800 and 1700 Hz, when ICP was ≥ 12 mmHg above baseline ICP, DPOAE angles increased significantly and DPOAE magnitudes decreased significantly, but less robustly. DISCUSSION Significant changes in DPOAE angle and magnitude are seen when ICP is ≥ 12 mmHg above a subject's supine baseline ICP during CSF infusion testing. These results suggest that the changes in DPOAE angle and magnitude seen with change in ICP are physiologically based, and suggest that it should be possible to detect pathological ICP elevation using DPOAE measurements. To use DPOAE for noninvasive estimation of ICP during spaceflight will require baseline measurements in the head-up, supine, and head-down positions to obtain baseline DPOAE values at different ICP ranges. Williams MA, Malm J, Eklund A, Horton NJ, Voss SE. Distortion product otoacoustic emissions and intracranial pressure during CSF infusion testing. Aerosp Med Hum Perform. 2016; 87(10):844-851.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Technical report: distortion product otoacoustic emissions that are not outer hair cell emissions.

PURPOSE To present a case study in order to alert clinicians to the possibility of occurrence of intermodulation distortion during otoacoustic emissions testing that arises from the cavity formed by the external auditory meatus and tympanic membrane rather than from the inner ear, compromising the reliability and validity of otoacoustic emissions testing. RESEARCH DESIGN Prospective case stud...

متن کامل

The E ect of Amplitude Modulated Contralateral Signals on Distortion Product Otoacoustic Emissions

Contralateral stimulation of the auditory system causes changes in levels of otoacoustic emissions. The main objective of this study was to determine the changes in the level of distortion product otoacoustic emissions for contralaterally presented unmodulated broad-band noise, or amplitude modulated broad-band noise. Two types of modulating signal were used in the investigations (sine or recta...

متن کامل

Transient Evoked and Distortion Product Otoacoustic Emissions in a Group of Neonates

Introduction The most commonly used method in neonatal hearing screening programs is transient evoked otoacoustic emissions in the first stage of the process. There are few studies comparing transient evoked otoacoustic emissions with distortion product, but some authors have investigated the issue. Objective To correlate the results of transient evoked and distortion product otoacoustic emissi...

متن کامل

A Finite Element Model of an Average Human Ear Canal to Assess Calibration Errors of Distortion Product Otoacoustic Emission Probes

Otoacoustic emissions (OAEs) are a class of acoustic signals that are generated in the cochlea and transmitted backward to the ear canal through the middle ear. This is attributed to the active nonlinear mechanism in the cochlea [Kemp 1978]. Distortion product otoacoustic emissions (DPOAEs) are a special type of OAEs generated in response to two pure tone acoustic stimuli with sound pressure le...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Aerospace medicine and human performance

دوره 87 10  شماره 

صفحات  -

تاریخ انتشار 2016