A clinical comparison of two commercially available pediatric hemoconcentrators.
نویسندگان
چکیده
Hemoconcentration is a technique that involves selective removal of plasma water and some dissolved solutes by way of an ultrafiltration membrane. Hemoconcentrators (HC) are routinely used during pediatric cardiopulmonary bypass (CPB) to remove free plasma water and various inflammatory mediators. This paper examines two different commercial HCs, the Dideco DHF0.2 and the Minntech Hemocor HPH 400. Both products were evaluated when used for prebypass ultrafiltration (Pre-BUF), and postbypass modified ultrafiltration (MUF). Five HCs were evaluated for each product, and the two groups were compared during the two different phases of the cardiac procedure. During the pre-BUF period, both groups of HCs were tested at a transmembrane pressure (TMP) gradient of 500 millimeters of mercury (mmHg). The mean amount of ultrafiltrate (UF) removed by the Dideco DHF0.2 was 81.4 milliliters per minute (mL/min), and the mean amount of UF removed by the Minntech Hemocor HPH 400 was 90.8 mL/min during the pre-BUF period. During the peribypass period flow parameters were much harder to define. As a result, these data are not reported. During the MUF procedure, the mean amount of UF removed by the Dideco DHF0.2 was 74.2 mL/min at an average MUF flow rate of 130 mL/min. The mean amount of UF removed by the Minntech Hemocor HPH 400 was 81.4 mL/min at an average MUF flow rate of 127 mL/min. Both products performed adequately under the clinical circumstances described above. The Minntech HPH 400 produced a hemofiltrate that was consistently tinged with a slight red color. The Dideco DHF0.2 consistently produced a hemofiltrate that was noticeably clearer than that of the Minntech device.
منابع مشابه
Comparison of dosimetry parameters of two commercially available Iodine brachytherapy seeds using Monte Carlo calculations
Background: Iodine brachytherapy sources with low photon energies have been widely used in treating cancerous tumors. Dosimetric parameters of brachytherapy sources should be determined according to AAPM TG-43U1 recommendations before clinical use. Monte Carlo codes are reliable tools in calculation of these parameters for brachytherapy sources. Materials and Methods: Dosimetric param...
متن کاملIn Vitro Comparison of Soybean Lecithin Based-Extender with Commercially Available Extender for Ram Semen Cryopreservation
Background Egg yolk is the main cryoprotectant agent in semen freezing extenders which is used in order to protect spermatozoa against cold shock. However elimination of animal bioproducts from the cryopreservation protocol is becoming mandatory. Therefore the aim of this study is to compare a previously studied homemade soya bean lecithin based extender with a commercially available extender f...
متن کاملClinical and Biochemical Assessments of Circulating B-Type Natriuretic Peptide as a Useful Marker in Pediatric Cardiac Patients
Background Although the left ventricle is the major site of BNP secretion in response to cardiac pressure or volume overload, the myocytes of both atria and ventricles secrete B- type natriuretic peptide (BNP). This study aimed to assess and compare the plasma levels of BNP in common pediatric cardiac diseases to clarify its pathophysiological role and evaluate its po...
متن کاملRadioprotection to the Gonads in Pediatric Pelvic Radiography: Effectiveness of Developed Bismuth Shield
Background: The use and effectiveness of traditional lead gonad shields in pediatric pelvic radiography has been challenged by several literatures over the past two decades. The aim of this study was to develop a new radioprotective gonad shields to be use in pediatric pelvic radiography. Materials and Methods: The commercially available 0.06 mm lead equivalent bismuth garment has cropped squar...
متن کاملPreoperative Sterilization Preparation of the Shoulder: A Comparative Study Evaluating Gauze Sponge and Commercially Available Applicator Prep Stick
Background: Surgical site infection (SSI) remains a concern in shoulder surgery, especially during arthroplasty. Whilemany studies have explored the characteristics and efficacy of different sterilizing solutions, no study has evaluated themethod of application. The purpose of this study was to compare two popular pre-surgical preparatory applications (two4 x 4 cm gauze sponges and applicator s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The journal of extra-corporeal technology
دوره 36 1 شماره
صفحات -
تاریخ انتشار 2004