Blood pressure randomized methodology study comparing automatic oscillometric and mercury sphygmomanometer devices: National Health and Nutrition Examination Survey, 2009-2010.

نویسندگان

  • Yechiam Ostchega
  • Guangyu Zhang
  • Paul Sorlie
  • Jeffery P Hughes
  • Debra S Reed-Gillette
  • Tatiana Nwankwo
  • Sarah Yoon
چکیده

OBJECTIVES The mercury sphygmomanometer has been the gold standard used for obtaining blood pressure (BP) for the National Health and Nutrition Examination Survey (NHANES) from 1960 to the present. However, due to environmental concerns and an increased use of automated oscillometric BP devices, NHANES has been exploring an alternative to using the standard mercury sphygmomanometer (mercury) to measure BP. METHODS The accuracy of Omron HEM-907XL BP readings was compared with that of mercury BP device readings for gender, age group, race and ethnicity, and body mass index categories and cuff-size subgroups. Each person had three BP measurements per device recorded sequentially. The order of the devices and readers were randomly assigned. A total of 6,460 participants had three valid systolic readings, and 6,338 had three valid diastolic readings. RESULTS Omron and mercury measurements were correlated (r = 0.92, systolic BP; r = 0.79, diastolic BP). Overall, the mean between-device differences (Omron and mercury) were -1.6 mm Hg for systolic and -0.6 mm Hg for diastolic (p < 0.05 for both). The mean between-device differences were less than or about 2 mm Hg for each subgroup: gender, age group, race and ethnicity, and body mass index categories, and cuff-size subgroups. The exceptions were mean systolic between-device differences for those using the extra-large BP cuff (-3.1 mm Hg) and obese individuals (-2.6 mm Hg), and the mean diastolic between-device differences for the underweight group (-3.5 mm Hg). Assuming mercury to be the gold standard, between-device agreements for the frequency of high BP (140/90 mm Hg or more) and stage II high BP (160/100 mm Hg or more) were above chance (kappa = 0.72 for both). Omron underestimated the high BP frequency by 2.28% and stage II high BP frequency by 0.77%. CONCLUSIONS Lower estimates of high BP by the Omron device may require adjusting future national prevalence estimates accordingly to account for between-device differences.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Challenges in standardization of blood pressure measurement at the population level

BACKGROUND Accurate blood pressure measurements are needed in clinical practice, intervention studies and health examination surveys. Blood pressure measurements are sensitive: their accuracy can be affected by measurement environment, behaviour of the subject, measurement procedures, devices used for the measurement and the observer. To minimize errors in blood pressure measurement, a standard...

متن کامل

Alternatives to the mercury sphygmomanometer.

The mercury sphygmomanometer was introduced over 100 years ago. Mercury, however, is a potent human neurotoxin. An international effort has developed to eliminate health-care sources of mercury--the thermometer and sphygmomanometer--and replace them with less toxic alternatives. There is concern regarding the accuracy of these alternative devices. We conducted a literature review of articles pu...

متن کامل

Validation of two automatic devices for the self-measurement of blood pressure according to the ANSI/AAMI/ISO81060-2:2009 guidelines: the Omron BP765 (HEM-7311-ZSA) and the Omron BP760N (HEM-7320-Z)

BACKGROUND Allowing patients to measure their blood pressure (BP) at home will be the standard for evaluating the disease state as the process of clinical diagnosis, and it is recognized as having great clinical utility. To measure BP as accurately as possible, innovative techniques have been incorporated into home BP measurement devices. OBJECTIVE The present study aimed to evaluate the perf...

متن کامل

Patient self-monitoring of blood pressure in general practice: the 'inverse white-coat' response.

Self-monitoring of blood pressure may give a truer estimate of usual blood pressure than readings by a doctor in the surgery, and may save time for health professionals. This study aimed to determine the accuracy of self-monitoring in the surgery using a wrist oscillometric sphygmomanometer (Omron RX). One hundred and seventy-three patients were taught to record their own blood pressure with th...

متن کامل

Agreement between the Takeda UA-731 automatic blood pressure measuring device and the manual mercury sphygmomanometer: an assessment under field conditions in Newcastle upon Tyne, UK.

STUDY OBJECTIVE To assess agreement between two Takeda UA-731 automatic blood pressure measuring devices (referred to as machines A and B) and two manual mercury sphygmomanometers. DESIGN A 'Y' connector attached each Takeda UA-731 to a manual mercury sphygmomanometer. Simultaneous measurements were made on adult subjects. SETTING A population based cardiovascular disease survey in Newcastl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • National health statistics reports

دوره 59  شماره 

صفحات  -

تاریخ انتشار 2012