In-situ calibration of rotating coil magnetic measurement systems: a case study on Linac4 magnets at CERN
نویسندگان
چکیده
Abstrac tAn in-situ procedure for calibrating the equivalent radius and width of the coil transducer in rotating mode measurements for magnetic field quality analysis is proposed. The standard calibration procedure is not suitable when the coil is longer than the magnet under test, because an average value of the radius and of the width along the length as a whole is obtained. This problem increases for small coils used in small-aperture magnets, such as quadrupoles of new-generation linear accelerators. In the paper, the problem of the coil parameter calibration is highlighted and then the proposed calibration method and the corresponding measurement station are illustrated. Experimental results of a case study on the magnet series of the new linear particle accelerator LINAC4, designed to intensify the proton flux currently available in the accelerator chain at the European Organization for Nuclear Research (CERN), are reported.
منابع مشابه
Measurement of Eddy Current Transients in Fast-cycled Linac Quadrupole Magnets at Cern
− The paper deals with a fast measurement technique of electromagnetic transients due to eddy currents in fast-cycled magnets for linear particle accelerators. First the context of the problem, related to the need for accurate control of the magnetic field quality in order to ensure the stability and performance of the particle beam in dynamic conditions (field ramps up to about 700 T/s) is out...
متن کاملاندازهگیری مغناطیسی (کنترل کیفیت) الکترومغناطیس چهار قطبی نمونه حلقه انبارش چشمه نورایران
Magnetic Measurement Lab is one of the most significant divisions of Research and Development (R&D) Lab of Iranian Light Source Facility. The main duty of this lab is to measure and check qualification of the accelerator magnets, including permanent and electromagnets, being applied in Iran for the fisrt time. The ILSF measurement lab consists of precise measurement equipment, in proportion to...
متن کاملتطبیق پذیری باریکه -H در قسمت انرژی پایین و متوسط ماشین Linac4 در سرن
Linac4 is the near future 160 MeV H- linear accelerator of the CERN presently under construction. It will replace the present Linac2 as injector of the proton accelerator complex in CERN. The Linac4 is composed of a 45 keV ion source, a Low Energy Beam Transport (LEBT), a 352.2 MHz Radio Frequency Quadrupole (RFQ), which accelerates the beam to 3 MeV, and a Medium Energy Beam Transport (MEBT), ...
متن کاملField Measurements of the Kek B-factory Dipole and Wiggler Magnets
The KEK B-Factory (KEKB) [1] consists of 3.5 GeV positron (LER) and 8.0 GeV electron (HER) rings and has more than 290 dipole and 150 wiggler magnets. Both the LER and the HER use four types of dipole magnets. Wiggler magnets are used for the LER. Three long flipflop coil systems were used to measure the transverse distribution of the integrated magnetic field along the beam direction. Each dip...
متن کاملCalibration of Rotating Coil Arrays for Particle Accelerator Magnet Testing
Synchrotron particle accelerators are mainly composed of magnets. Long dipole magnets are employed to bend and to contain the beam within a circular trajectory. Their field quality is usually tested by arrays of rotating coils. Typically the measurements must be affected by low uncertainty (+10) and the calibration of the sensing coils, in terms of surface and angle, is critical. In this paper,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2010