Successful closed reduction of refractured wrist with a bent volar distal radius plate.

نویسندگان

  • Ghislain F A E Geurts
  • Roger P Van Riet
  • Frederik Verstreken
چکیده

A case is presented of a 78-year-old woman who sustained a re-fracture of the distal radius after initial fixation with a volar locking plate. The fracture was located in the mid-portion of the volar plate with palmar apex bending of the plate and signs of median nerve compression. A successful closed reduction was performed without hardware failure. The fracture united uneventfully.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report

We describe a 59-year-old man who had nonunion of a right distal radius fracture after volar locking plate fixation. He underwent open reduction and internal fixation with a volar locking plate system for a dorsally displaced, unstable distal radius fracture at a previous hospital 5 months ago. Radiographs of the injured wrist showed nonunion of the distal radius with 1.5-mm ulnar minus varianc...

متن کامل

Volar Distal Radius Anatomy Applied to the Treatment of Distal Radius Fracture.

Volar locking plate (VLP) fixation has become the standard surgical treatment for distal radius fractures. However, flexor tendon rupture is one of the major complications following volar plating. This detailed review on the anatomy and morphology of the volar distal radius might facilitate appropriate placement of the volar plate and thereby avoid flexor tendon rupture. We introduce safe and s...

متن کامل

Anterior interosseous nerve palsy mimicking rupture of the index flexor digitorum profundus after volar locking plate fixation of a distal radius fracture

We describe the case of a patient with distal radius fracture who became unable to flex the distal interphalangeal joint of the index finger after internal fixation using a volar locking plate. There was palpable crepitus with active thumb motion, and wrist radiographs showed prominence of the volar plate at the watershed line. Therefore, our initial diagnosis was plate-induced closed rupture o...

متن کامل

Surgery versus conservative treatment in patients with type A distal radius fractures, a randomized controlled trial

BACKGROUND Fractures of the distal radius are common and account for an estimated 17% of all fractures diagnosed. Two-thirds of these fractures are displaced and require reduction. Although distal radius fractures, especially extra-articular fractures, are considered to be relatively harmless, inadequate treatment may result in impaired function of the wrist. Initial treatment according to Dutc...

متن کامل

Efficacy of radial styloid targeting screws in volar plate fixation of intra-articular distal radial fractures: a biomechanical study in a cadaver fracture model

BACKGROUND The locking screws target the radial styloid, theoretically provide greater stability against radial styloid fragment. However, it is unknown whether the radial styloid locking screws increased the stability of the volar plating system fixation along the entire distal radius or not. In this study, we evaluated the stability of the volar plating system fixation with or without the rad...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta orthopaedica Belgica

دوره 78 1  شماره 

صفحات  -

تاریخ انتشار 2012