Evaluation of keyed fillers on TEC vaporizers.

نویسندگان

  • W Richardson
  • K B Carter
چکیده

Single and dual port versions of the keyed fillers fitted to TEC4 and TEC3 vaporizers, respectively, were examined. The single port filler performed satisfactorily, provided that it was correctly used and properly maintained. Design deficiencies in the dual-port keyed filler were found which accounted for many of the problems described by users. The keyed bottle adaptor could be improved by an increase in its length and the provision of two openings into the outer tube at the bottle end.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Overfill testing of anaesthetic vaporizers.

We tested six anaesthetic vaporizers with keyed filler adaptors to see if it was possible to overfill them. For those vaporizers which could be overfilled, the maximum level of overfill was determined and the effect of overfilling on the vaporizer output concentration was measured. Three of the vaporizers, the TEC 4, PPV Mk 1 and MIE Vapamasta 5, could be overfilled. In the case of the TEC 4 an...

متن کامل

The desflurane Tec 6 vaporizer.

A late development model of the Tec 6 vaporizer for the administration of desflurane vapour has been evaluated. It is heated electrically and has both electronic monitors of vaporizer function and alarms. The new filling system is a significant improvement over previous Tec filling systems. The vaporizer requires a warm-up period before it may be used, but when activated it provides an output t...

متن کامل

Evaluation of the Efficiency of the Adaptive Neuro Fuzzy Inference System (ANFIS) in the Modeling of the Ionosphere Total Electron Content Time Series Case Study: Tehran Permanent GPS Station

Global positioning system (GPS) measurements provide accurate and continuous 3-dimensional position, velocity and time data anywhere on or above the surface of the earth, anytime, and in all weather conditions. However, the predominant ranging error source for GPS signals is an ionospheric error. The ionosphere is the region of the atmosphere from about 60 km to more than 1500 km above the eart...

متن کامل

Comparative clinical assessment of two nasolabial hyaluronic acid fillers: A double-blind, randomized controlled trial

Background: Various fillers have been used for the correction of nasolabial folds. This study investigated the efficacy and safety assessment of two hyaluronic acid (HA) fillers on moderate nasolabial folds. Methods: This study randomized 10 volunteers, aged 35 to 49 years, with moderate nasolabial folds. Volunteers received injections of HA A and HA B gels into the right or left skin folds. Th...

متن کامل

Digital Binary Phase-shift Keyed Signal Detector

We have developed the effective algorithm for detecting digital binary phase-shift keyed signals. This algorithm requires a small number of arithmetic operations over the signal period. It can be relatively easy implemented based on the modern programmable logic devices. It also provides high interference immunity by identifying signal presence when signal-to-noise ratio is much less that its w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 58 3  شماره 

صفحات  -

تاریخ انتشار 1986