The Determination of when Routine Internal Dosimetry Monitoring Is Required

نویسنده

  • Gareth Roberts
چکیده

Routine internal dose exposures are typically (in the UK nuclear industry) less than external dose exposures: however, the costs of internal dosimetry monitoring programmes can be significantly greater than those for external dosimetry. For this reason decisions on when to apply routine monitoring programmes, and the nature of these programmes, can be more critical than for external dosimetry programmes. The UK Ionising Radiations Regulations [1] require that all significant doses are assessed and recorded, and the Approved Code of Practice [2] advise that decisions on when monitoring is required is determined by the expected magnitude and variability of personal dose. This leaves the practical problem of how to quantify the expected dose while avoiding the “Catch-22” situation of implementing extensive monitoring programmes simply to provide evidence that they were not required. This paper describes various internal dosimetry risk assessment methods which are employed by Nuvia Limited Approved Dosimetry Services to attempt to provide an objective assessment of when routine internal dosimetry monitoring should be considered. It also discusses the possible shortcomings of these process and potential future development. The paper argues that, for most instances in the nuclear industry, the principle objective of routine internal monitoring programmes is not to monitor exposure to internal dose, but to monitor for the risk of exposure; thereby indicating when more thorough investigations and dose estimation is required, and also providing important feedback to the efficacy of radiological protection measures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

InRaDoS: An internal radiation dosimetry computer program

Introduction: Internal radiation dosimetry is important from a radiation protection point of view and can help to optimize the radiation dose delivered to the workers, public, and patients. It has a rather simple protocol but needs a large amount of data. Therefore, it is difficult to do on a routine basis. The use of computer programs makes internal radiation dosimetry simpler...

متن کامل

Determination of organ doses in radioiodine therapy using medical internal radiation dosimetry (MIRD) method

Background: Radioiodine therapy has proven to be an effective method in the treatment of patients with differentiated thyroid carcinoma after thyroidectomy. The scope of this study is to describe a method to obtain the dose of organs using medical internal radiation dosimetry (MIRD) method. At the end, the results of MIRD calculations were compared with thermoluminescent dosimeter (TLD...

متن کامل

Development of Prototype Iranian male pelvic phantom for internal dosimetry

Introduction: Existing phantoms have been constructed based on Caucasian, non-Caucasian and race-specific datasets. According to previous studies made efforts to present Korean- specific phantoms and Chinese female phantom based on CVH dataset due to compare the resulting internal dosimetry with the Caucasian based data showed possible racial difference in human anatomy between ...

متن کامل

Dosimetry in Targeted Radionuclide Therapy: The Bad Berka Dose Protocol—Practical Experience

Aim: Calculating the absorbed dose is important for the determination of risk and therapeutic benefit of internal radiation therapy. Optimal dose estimations require time-consuming and sophisticated methods, which are difficult due to practical reasons. To make dosimetry available for each of the patients, we developed a specific dosimetry procedure used in daily clinical routine. Materials and...

متن کامل

Monitoring Intakes of Pu/Am by External Counting: Current Status in India

INTRODUCTION The current practice of internal dosimetry for occupational workers handling actinides, in particular Pu/Am, involves monitoring of intakes. This, in turn, requires assessments of internal actinide contamination of the relevant body organs. Such assessments are needed: a) more often and almost on a routine basis for lungs for the recent as well as old exposures; b) comparatively le...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010