Effect of dental implant diameter on fatigue performance. Part I: mechanical behavior.
نویسندگان
چکیده
AIM The purpose of this study was to evaluate the effect of the implants' diameter on the mechanical function and load-fatigue performance of dental implants. MATERIALS AND METHODS Three groups of implants with different diameters (3.3 mm, 3.75 mm and 5 mm), were tested under static and cyclic compressive loading. A total number of 15 implants for the static test and 112 implants for the cyclic-fatigue test. In the cyclic test, the machine ceased operating when the structure collapsed or when it reached 5 × 10(6) cycles without apparent failure. The load versus the number of cycles was plotted as curves for biomechanical analysis (S-N curve) for each implant diameter. RESULTS The S-N curve plotted for the 5 mm implants showed classic fatigue behavior with a finite life region starting from 620N. The same was observed for the 3.75 mm diameter implants, with a finite life region starting below 620N. By contrast, the 3.3 mm diameter implants failed to show predictable fatigue behavior and a fatigue limit could not be defined. CONCLUSIONS The results of this study emphasize the importance of implant diameter on fatigue behavior. Narrow implants failed to show typical fatigue behavior which might be attributed to the implant design.
منابع مشابه
Effect of Coating Materials on the Fatigue Behavior of Hip Implants: A Three-dimensional Finite Element Analysis
This study aims to validate, using finite element analysis (FEA), the design concept by comparing the fatigue behavior of hip implant stems coated with composite (carbon/PEEK) and polymeric (PEEK) coating materials corresponding to different human activities: standing up, normal walking and climbing stairs under dynamic loadings to find out which of all these models have a better performance in...
متن کاملCORROSION BEHAVIOR OF BIOACTIVATED TITANIUM DENTAL IMPLANT USING DIFFERENT CHEMICAL METHODS
At the past, damaged tissue was removed from the body of patients. But now tissue regeneration using scaffolds and implants are used to repair the damaged tissue and organs. Besides of the mechanical properties of metallic biomaterials, they suffer from bioinertness. Using some surface treatment techniques, the bioactivity and also corrosion resistance of titanium implants could be improved. In...
متن کاملStudying on the fatigue behavior of Al- Al2O3 metal matrix nano composites processed through powder metallurgy
Excellent mechanical properties and fatigue performance of Al/Al2O3 metal-based nanocomposites caused to introduce this material as a good candidate for various applications. In this regard, the preparation and characterization of this composite can be considered as a hot issue for research. The study was carried out in several steps including: (i) preparation of Al/Al2O3 metal-based nanocompos...
متن کاملImproved fatigue life of acrylic bone cements reinforced with zirconia fibers.
Poly(methyl methacrylate) (PMMA) bone cements have a long and successful history of use for implant fixation, but suffer from a relatively low fracture and fatigue resistance which can result in failure of the cement and the implant. Fiber or particulate reinforcement has been used to improve mechanical properties, but typically at the expense of the pre-cured cement viscosity, which is critica...
متن کاملFatigue of Dental Implants: Facts and Fallacies
Dental implants experience rare yet problematic mechanical failures such as fracture that are caused, most often, by (time-dependent) metal fatigue. This paper surveys basic evidence about fatigue failure, its identification and the implant's fatigue performance during service. We first discuss the concept of dental implant fatigue, starting with a review of basic concepts related to this failu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical implant dentistry and related research
دوره 16 2 شماره
صفحات -
تاریخ انتشار 2014