In vitro evaluation of torsional strength of orthodontic mini-implants

نویسندگان

  • Matheus Melo Pithon
  • Rogério Lacerda dos Santos
  • Carla D’Agostini Derech
  • Carlos Nelson Elias
  • Lincoln Issamu Nojima
چکیده

Matheus Melo Pithon; Rogério Lacerda dos Santos; Carla D’Agostini Derech; Carlos Nelson Elias; Antônio Carlos de Oliveira Ruellas; Lincoln Issamu Nojima DDS, Specialist in Orthodontics, Dental School, Federal University of Alfenas, Brazil; Student of the Doctor’s Degree Program in Orthodontics, Dental School, Federal University of Rio de Janeiro, Brazil. DDS, Student of the Master’s Degree Program in Orthodontics, Dental School, Federal University of Rio de Janeiro, Brazil. DDS, MSc, PhD, Professor, Department of Metallurgical Engineering, Fluminense Federal University, Brazil. DDS, MSc, PhD, Adjunct Professor of Orthodontics, Dental School, Federal University of Rio de Janeiro, Brazil.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fracture strength of orthodontic mini-implants

Objective: This study aimed at evaluating the design and dimensions of five different brands of orthodontic mini-implants, as well as their influence on torsional fracture strength. Methods: Fifty mini-implants were divided into five groups corresponding to different manufactures (DEN, RMO, CON, NEO, SIN). Twenty-five mini-implants were subjected to fracture test by torsion in the neck and t...

متن کامل

Design characteristics, primary stability and risk of fracture of orthodontic mini-implants: Pilot scan electron microscope and mechanical studies

OBJECTIVE Orthodontic mini-implants (OMIs) are increasingly used in orthodontics but can fail for various reasons. This study investigates the effects of OMI design characteristics on the mechanical properties in artificial bone. MATERIAL AND METHODS Twelve self-drilling OMIs (2 small, 6 medium, 4 large) from 8 manufacturers were tested for their primary stability in simulated medium-high can...

متن کامل

Clinical indices for orthodontic mini-implants.

Orthodontic mini-implants were recently developed and have been widely used in clinics. However, loosening of mini-implants, as well as infection and swelling of mucosal tissue at the placement site, are often observed during orthodontic treatment. Thus, clinical indices are greatly needed for the safe use of orthodontic mini-implants. This article presents information on mini-implants and offe...

متن کامل

Evaluation of Fracture Resistance of Orthodontic Mini-implants in the Transmucosal Profile Region.

AIM This study sought to compare the fracture resistance of three trademarked orthodontic mini-implants in the transmucosal profile region. Thirty-six mini-implants of three different brands, separated into groups I, II and III, were tested. Each group consisted of 12 mini-implants of 6 mm in length. The mean diameter and length of the transmucosal profile of the mini-implants were 1.90 and 2.0...

متن کامل

Evaluation of cytotoxicity and corrosion resistance of orthodontic mini-implants

Objective: To evaluate and compare in vitro cytotoxicity and corrosion resistance of mini-implants from three different commercial brands used for orthodontic anchorage. Methods: Six mini-implants (Conexão(tm), Neodent(tm) and SIN(tm)) were separately immersed in artificial saliva (pH 6.76) for 30 and 60 days. The cytotoxicity of the corrosion extracts was assessed in L929 cell cultures usin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008