Cementing polyethylene liners into non-modular acetabular components in revision total hip arthroplasty.

نویسندگان

  • Harpal S Khanuja
  • Ajay Aggarwal
  • Marc W Hungerford
  • David S Hungerford
  • Lynne C Jones
  • Michael A Mont
چکیده

PURPOSE To review mid-term results after replacing the polyethylene liner in a well-fixed acetabular shell. METHODS 22 patients underwent replacement of the polyethylene liner in a well-fixed acetabular shell using cementation. The inner surface of the metal shell was scored with grooves (1 to 2 mm deep) for cement interdigitation. Trial liners were used to assess the appropriate size, with an aim to provide at least 2 mm of an even cement mantle behind the polyethylene liner. None of the liners were constrained or lipped. Clinical and radiographic outcomes were evaluated, and Harris Hip Scores obtained. Radiographic loosening of the acetabular shell was recorded. Implant survival was evaluated using the Kaplan- Meier estimator. RESULTS After a mean follow-up of 70 (range, 21-189) months, 17 patients had stable hips and their mean Harris Hip Score was 89 (range, 72-93). Four patients underwent re-revision after 28 to 108 months for aseptic loosening of the acetabular shell (n=2) and recurrent dislocation (n=2). One patient showed radiographic evidence of acetabular migration but was stable. The femoral components of all patients were stable. 92% of patients had good-to-excellent results. Implant survival at 60 months was 81% (95% confidence interval [CI], 51-94%); it became 91% (95% CI, 61-99%) if reductions for dislocations were excluded. CONCLUSION Cementation of an undersized polyethylene liner into a non-modular shell is one option for revision of a well-fixed acetabular shells. Nonetheless, further follow-up is required to determine if it remains a viable option in the long term. If there is any doubt about the stability of the acetabular shell, a complete revision should be performed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cementation of a dual-mobility acetabular component into a well-fixed metal shell during revision total hip arthroplasty: a biomechanical validation.

Cementation of polyethylene (PE) liners into well-fixed metal shells has become a popular option during revision total hip arthroplasty (THA) particularly for older and frail patients. Although dramatic results were reported with dual-mobility acetabular components to manage hip instability during revision THA, no study evaluated the fixation strength of the cementation of dual-mobility compone...

متن کامل

Highly cross-linked polyethylene acetabular liners retrieved four to five years after revision surgery: a report of two cases.

There is currently considerable interest in the use of highly cross-linked polyethylene (XLPE) acetabular liners for total hip arthroplasty (THA). In literature, only a single retrieval analysis of one type of XLPE liner implanted for greater than four years exists. The purpose of the present report is to quantify surface deviations in two XLPE liners implanted during revision THA and retrieved...

متن کامل

Metal-backed acetabular components with conventional polyethylene: a review of 9113 primary components with a follow-up of 20 years.

The Norwegian Arthroplasty Register has shown that several designs of uncemented femoral stems give good or excellent survivorship. The overall findings for uncemented total hip replacement however, have been disappointing because of poor results with the use of metal-backed acetabular components. In this study, we exclusively investigated the medium-to long-term performance of primary uncement...

متن کامل

Revision of an acetabular liner has a high risk of dislocation.

Polyethylene liners of modular acetabular components wear sometimes need to be replaced, despite the metal shell being well fixed. Replacing the liner is a relatively simple procedure, but very little is known of the outcome of revision. We prospectively followed up 1126 Harris-Galante I metal-backed, uncemented components for between nine and 19 years. We found 38 (3.4%) liners of 1126 acetabu...

متن کامل

Midterm results of 506 solid trispiked reflection cementless acetabular components for primary total hip arthroplasty.

The purpose of this prospective study was to evaluate the outcomes and survivorship of a trispiked, sintered bead-coated titanium shell with a polished inner surface, no screw holes, and an improved locking mechanism. A total of 506 total hip arthroplasties with a minimum 5-year follow-up were available for review at a mean of 7 years (range, 5-11 years). Three sockets (0.6%) were revised for r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic surgery

دوره 18 2  شماره 

صفحات  -

تاریخ انتشار 2010