Breakage of intramedullary femoral guide rod during total knee arthroplasty: a case report.

نویسندگان

  • W L Chan
  • C H Yen
  • K K Wong
  • P Y T Tse
  • K H Mak
چکیده

We report a rare complication during primary total knee arthroplasty. An intramedullary femoral guide rod was broken during insertion. The broken part jammed into the isthmus of the femur. An initial attempt to push the broken rod via the proximal femur by a guide wire to the distal femur was unsuccessful because the broken rod was lodged in the isthmus. Ultimately, the isthmus was opened using a flexible 9-mm end-cutting reamer, and the broken rod was pushed down to the distal femoral entry site in an antegrade fashion under image intensification. Selecting a more medial entry site on the intercondylar notch with a smaller valgus cutting angle and using a shorter guide rod can avoid such a breakage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An intramedullary alignment guide lodging within the femoral canal during total knee arthroplasty: a case report.

The usual complications of total knee arthroplasty include thrombo-embolism, infection, and loosening. We report an unusual and potentially serious complication of an intramedullary guide lodging within the femoral canal during the procedure. Considering the risk of fracture and additional exposure, the guide was not removed and was cut in situ. The rest of the operation was completed successfu...

متن کامل

Navigation-Assisted Total Knee Arthroplasty for the Knee Retaining Femoral Intramedullary Nail, and Distal Femoral Plate and Screws

Proper ligament balancing, restoration of the mechanical axis and component alignment are essential for the success and longevity of a prosthesis. In conventional total knee arthroplasty (TKA), an intramedullary guide is used to improve the alignment. An extramedullary guide can be used in cases of severe femoral bowing or intramedullary nailing but its use is more subjective and relies on the ...

متن کامل

Different References for Valgus Cut Angle in Total Knee Arthroplasty

Background: The valgus cut angle (VCA) of the distal femur in Total Knee Arthroplasty (TKA) is measured preoperativelyon three-joint alignment radiographs. The anatomical axis of the femur can be described as the anatomical axis of thefull length of the femur or as the anatomical axis of the distal half of the femur, which may result in different anglesin some cases. During TKA, the anatomical ...

متن کامل

Extramedullary versus intramedullary femoral alignment technique in total knee arthroplasty: a meta-analysis of randomized controlled trials

BACKGROUND There is no consensus whether the use of the extramedullary femoral cutting guide takes advantage over the intramedullary one in total knee arthroplasty. The aim of this study was to compare the extramedullary femoral alignment guide system with the conventional intramedullary alignment guide system for lower limb alignment, blood loss, and operative time during total knee arthroplas...

متن کامل

TKA after clamshell osteotomy for femoral diaphyseal malunion.

Proper component positioning is essential for successful total knee arthroplasty (TKA). Femoral component positioning presents a technical challenge when significant femoral deformity is present. Most commonly, an intramedullary guide is used to make an accurate distal femoral cut. However, in the presence of a significant femoral deformity, this is not a viable option.The use of clamshell oste...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic surgery

دوره 14 1  شماره 

صفحات  -

تاریخ انتشار 2006