Effect of UV light disinfection on antibiotic-resistant coliforms in wastewater effluents.

نویسنده

  • M C Meckes
چکیده

Total coliforms and total coliforms resistant to streptomycin, tetracycline, or chloramphenicol were isolated from filtered activated sludge effluents before and after UV light irradiation. Although the UV irradiation effectively disinfected the wastewater effluent, the percentage of the total surviving coliform population resistant to tetracycline or chloramphenicol was significantly higher than the percentage of the total coliform population resistant to those antibiotics before UV irradiation. This finding was attributed to the mechanism of R-factor-mediated resistance to tetracycline. No significant difference was noted for the percentage of the surviving total coliform population resistant to streptomycin before or after UV irradiation. Multiple drug resistance patterns of 300 total coliform isolates revealed that 82% were resistant to two or more antibiotics. Furthermore, 46% of these isolates were capable of transferring antibiotic resistance to a sensitive strain of Escherichia coli.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Disinfection efficiency of secondary effluents with ultraviolet light in a Mediterranean area

This paper deals with the study of physicochemical and microbiological parameters affecting disinfection efficiency of secondary effluents in a municipal wastewater treatment plant, for irrigation purposes. There appears to be an important increase on turbidity values as chlorine values increases, due to the conversion of particulate organic carbon into dissolved organic carbon. The nitrificati...

متن کامل

Bacteriological quality of effluent submitted consecutively to a macrofiltration and ultraviolet light systems in the Tunisian conditions

This paper deals with the study of bacteriological quality of effluents that have undergone consecutively different macrofiltration system (pressure sand filter or disc filter used as a secondary treatment) and UV254 irradiation process (used as a tertiary treatment). These two successive systems of treatment were evaluated to determine their possible application as commonly alternatives to the...

متن کامل

Disinfection of Primary Municipal Wastewater Effluents Using Continuous UV and Ozone Treatment

UV radiation and ozonation were investigated as disinfection alternatives for the wastewater treatment plant. The inactivation of total and fecal coliforms using ozone and ultraviolet radiation as separate treatments was evaluated. Different ozone concentrations (3 to 40 mg O3/L) were applied and UV fluencies ranging from 8.5 to 12 mJ/cm at different pH values (from 5 to 9) were tested. Best re...

متن کامل

Improved wastewater disinfection by ultrasonic pre-treatment.

The objective of our work is to evaluate the scientific and economic potential of US application as a pre-treatment step in combination with UV to optimise the disinfection process of wastewaters. Ultrasound application of 20 s at low density of 30 W/l changed the particle size distribution (PSD) of the samples, the mean particle diameter dropped from 70 to 11 microm. Generally it is assumed th...

متن کامل

Urban wastewater disinfection by filtration technologies

The microbiological quality of effluents from different macrofiltration systems (pressure sand filter and disc filter) used as pre-treatment and membrane technologies (microfiltration and ultrafiltration) was evaluated in order to determine their possible application as alternatives to disinfection of urban wastewater prior to reutilization. Microbiological quality was determined by reference t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Applied and environmental microbiology

دوره 43 2  شماره 

صفحات  -

تاریخ انتشار 1982