Percutaneous Epicardial Pacing using a Novel Insulated Multi-electrode Lead.

نویسندگان

  • Faisal F Syed
  • Christopher V DeSimone
  • Elisa Ebrille
  • Prakriti Gaba
  • Dorothy J Ladewig
  • Susan B Mikell
  • Scott H Suddendorf
  • Emily J Gilles
  • Andrew J Danielsen
  • Markéta Lukášová
  • Jiří Wolf
  • Pavel Leinveber
  • Miroslav Novák
  • Zdeněk Stárek
  • Tomas Kara
  • Charles J Bruce
  • Paul A Friedman
  • Samuel J Asirvatham
چکیده

INTRODUCTION Epicardial cardiac resynchronization therapy (CRT) permits unrestricted electrode positioning. However, this requires surgical placement of device leads and the risk of unwanted phrenic nerve stimulation. We hypothesized that shielded electrodes can capture myocardium without extracardiac stimulation. METHODS In 6 dog and 5 swine experiments, we used a percutaneous approach to access the epicardial surface of the heart, and deploy novel leads housing multiple electrodes with selective insulation. Bipolar pacing thresholds at prespecified sites were tested compare electrode threshold data both facing towards and away from the epicardial surface. RESULTS In 151 paired electrode recordings (70 in 6 dogs; 81 in 5 swine), thresholds facing myocardium were lower than facing away (median [IQR] mA: dogs 0.9 [0.4-1.6] vs 4.6 [2.1 to >10], p<0.0001; swine 0.5 [0.2-1] vs 2.5 [0.5-6.8], p<0.0001). Myocardial capture was feasible without extracardiac stimulation at all tested sites, with mean ± SE threshold margin 3.6±0.7 mA at sites of high output extracardiac stimulation (p=0.004). CONCLUSION Selective electrode insulation confers directional pacing to a multielectrode epicardial pacing lead. This device has the potential for a novel percutaneous epicardial resynchronization therapy that permits placement at an optimal pacing site, irrespective of the anatomy of the coronary veins or phrenic nerves.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acute and chronic performance evaluation of a novel epicardial pacing lead placed by percutaneous subxiphoid approach in a canine model.

BACKGROUND Endovascularly implanted leads risk vascular injury and endocarditis, and can be difficult to locate in desired positions for LV pacing. We evaluated the acute and long-term stability, electric performance and histopathology of a percutaneously placed intrapericardial lead (IPL). METHODS AND RESULTS Twelve adult mongrel dogs underwent defibrillator implants incorporating IPLs. Succ...

متن کامل

A new low threshold platinized epicardial pacing electrode: comparative evaluation in immature canines.

A prospective comparison of pacing and sensing capabilities between the conventional Medtronic Model 4951 platinum-iridium epicardial pacing electrode and a new modified "platinized" version of the same electrode was performed in immature canines to determine if the new electrode design improves pacing in the immature myocardium. The conventional electrode was modified by electroplating platinu...

متن کامل

Novel Technique of Dual Chamber Pacing Through Mini-thoracotomy and Transatrial Endocardial Active Fixation Lead Insertion for Epicardial Pacing Lead Malfunction

Epicardial pacing lead fixation is employed in patients with cavopulmonary anastamosis (Glenn shunts) when they need permanent pacing. Epicardial pacing in these patients may malfunction due to high pacing thresholds or diaphragmatic pacing. A novel technique of transatrial insertion of two endocardial screw-in pacing leads through right anterolateral minithoracotomy could achieve synchronous a...

متن کامل

Pericardial complications of endocardial and epicardial pacing.

A patient with complete atrioventricular block was fitted with a temporary endocardial pacing wire via a right subclavian percutaneous approach. The result was initially satisfactory, but within a few days radiography for left-sided chest pain showed pneumopericardium. A permanent epicardial pacing system was therefore substituted and she remained well for three months. She was then admitted fo...

متن کامل

Do daily threshold trend fluctuations of epicardial leads correlate with pacing and sensing characteristics in paediatric patients?

AIMS To evaluate whether the magnitude of daily ventricular pacing threshold fluctuations (Deltafluctuation) in trend graphs of stored diagrams correlate with ventricular threshold and sensing changes over time. METHODS AND RESULTS A total of 56 children received AutoCapture devices (St. Jude Medical, Sylmar, CA, USA) connected to steroid-eluting epicardial leads. Maximum lead age at study cl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • JACC. Clinical electrophysiology

دوره 1 4  شماره 

صفحات  -

تاریخ انتشار 2015