On-site determination of microalbuminuria based on Particle- Enhanced Turbidimetric-Inhibition Immunoassay (PETINIA) by portable fiber-optic spectrometer

نویسندگان

  • Warattaya Sinwat
  • Assawapong Sappat
  • Adisorn Tuantranont
  • Wanida Laiwattanapaisal
چکیده

A homemade fiber-optic spectrometer has been fabricated for portable and on-site determination of microalbuminuria. The principle of the method was based on particle-enhanced turbidimetric-inhibition immunoassay (PETINIA), which was not affected by the hook effect phenomenon. This method was linear from 0 to 150 mg L (r = 0.987), with a detection limit of 3.01 mg L (S/N = 3). The intra-assay coefficient of variations (CVs) ranged from 3.1 4.8%, and the inter-assay CV was 6.7%, as assessed by calibration curves performed on three consecutive days. The precision of 10 replicate measurements of 50 mg L HSA in a single analytical run was 6.5%. Interfering compound tests were satisfactory with recoveries of 95.0% to 105.8%. The system demonstrated its applicability to perform accurate measurements outside the laboratory for in-field analysis of the microalbuminuria (MAU) assay. The albumin concentrations in real urine samples measured by this system correlated well with the particle-enhanced turbidimetric immunoassay performed on a conventional spectrophotometer with r = 0.996 (n = 58).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Particle-enhanced turbidimetric inhibition immunoassay for theophylline evaluated with the Du Pont aca.

We evaluated the Du Pont Particle-Enhanced Turbidimetric Inhibition Immunoassay (PETINIA) for theophylline. The imprecision (CV) of the assay was less than 4.7% between-run and less than 3.6% within-run for theophylline concentrations between 5 and 30 mg/L. Standard curves for the assay were linear for theophylline concentrations from 0 to 46 mg/L and were stable throughout the study (i.e., for...

متن کامل

Estimation of carbamazepine and carbamazepine-10,11-epoxide concentrations in plasma using mathematical equations generated with two carbamazepine immunoassays.

Carbamazepine is metabolized to an active metabolite known as carbamazepine-10,11-epoxide, or simply the "epoxide" metabolite. The presence of this metabolite can have clinically significant implications in therapeutic drug monitoring of carbamazepine, but accurate quantification of the epoxide metabolite is currently limited to chromatographic techniques. In this study, mathematical equations ...

متن کامل

Comparison of PETINIA and LC-MS/MS for determining plasma mycophenolic acid concentrations in Japanese lung transplant recipients

Background Mycophenolic acid (MPA) treatment requires therapeutic drug monitoring to improve the outcome after organ transplantation. The aim of this study was to compare two methods, a particle enhanced turbidimetric inhibition immunoassay (PETINIA) and a reference liquid chromatography tandem mass spectrometry (LC-MS/MS) for determining plasma MPA concentrations from Japanese lung transplant ...

متن کامل

A quantitative automated immunoassay for fibrinogen/fibrin degradation products.

We describe a prototype quantitative automated assay for fibrin and fibrinogen degradation products, a particle-enhanced turbidimetric inhibition immunoassay (PETINIA) in the Du Pont aca discrete clinical analyzer. This assay involves a latex particle reagent with covalently bound fibrinogen and a polyclonal antiserum raised in rabbits against human fibrinogen. A special secondary sample-collec...

متن کامل

On-Chip Immunoassay for Determination of Urinary Albumin

An immunoassay performed on a portable microfluidic device was evaluated for the determination of urinary albumin. An increase in absorbance at 500 nm resulting from immunoagglutination was monitored directly on the poly(dimethylsiloxane) (PDMS) microchip using a portable miniature fibre-optic spectrometer. A calibration curve was linear up to 10 mg L(-1) (r(2) = 0.993), with a detection limit ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012