Evaluation of the influence of corneal biomechanical properties on intraocular pressure measurements using the ocular response analyzer.

نویسندگان

  • Felipe A Medeiros
  • Robert N Weinreb
چکیده

PURPOSE The Ocular Response Analyzer (ORA) proposes to measure corneal biomechanical properties in vivo by monitoring and analyzing the corneal behavior when this structure is submitted to a force induced by an air jet. The purpose of this study was to evaluate the relationship between corneal biomechanical properties and corneal-compensated intraocular pressure (IOPCC) measurements as obtained by the ORA and Goldmann applanation tonometry (GAT) measurements. DESIGN Observational clinical study. METHODS The study included 153 eyes of 78 subjects. All subjects underwent IOP evaluation with the ORA and GAT, and also measurements of central corneal thickness (CCT), corneal curvature, and axial length. Univariable and multivariable regression analysis were used to evaluate the associations between IOP (as measured with GAT and ORA) and CCT, corneal curvature, axial length, and age. Bland and Altman plots were used to evaluate the agreement between IOP measurements obtained by GAT and ORA. RESULTS GAT IOP measurements were significantly associated with CCT (P=0.001) and corneal curvature (P<0.001), whereas ORA IOPCC measurements were not associated with any of the ocular variables. The difference between GAT and IOPCC measurements was significantly influenced by corneal thickness. Patients with thicker corneas tended to have higher GAT IOP measurements compared with IOPCC, whereas in patients with thin corneas, GAT IOP measurements tended to be lower than IOPCC. CONCLUSIONS ORA IOPCC measurements seem to provide an estimate of IOP that is less influenced by corneal properties than those provided by GAT.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea

Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...

متن کامل

Ocular Response Analyzer

Until recently, corneal biomechanical properties could not be measured in vivo. The ocular response analyzer is a new, noninvasive device that analyses corneal biomechanical properties simply and rapidly. The ORA allows cornea compensated IOP measurements and can estimate corneal hysteresis (CH) and corneal resistance factor (CRF). It is designed to improve the accuracy of IOP measurement by us...

متن کامل

Effect of Ocular Biomechanics on Intraocular Pressure Measurement in Mucopolysaccharidosis I-S (Scheie’s Syndrome)

Purpose: To study the effect of biomechanical properties of the cornea on the intraocular pressure in eyes affected with Mucopolysaccharidosis type I-S (Scheie's syndrome). Methods: Four eyes of two patients in their mid-fifties diagnosed with Scheie's syndrome were investigated for corneal biomechanical properties. The corneal biomechanical profile was assessed by the use of Ocular response an...

متن کامل

Evaluation of Corneal Biomechanical Properties following Scleral Buckling Using the Ocular Response Analyzer

Purpose: To evaluate corneal visco-elasticity and intraocular pressure (IOP) changes measured by an Ocular Response Analyzer (ORA) after scleral buckling Methods: Fifty-six eyes with history of scleral buckling surgery three months ago were included in the study. Corneal hysteresis (CH), corneal resistance factor (CRF), corneal-compensated IOP (IOPcc) and Goldmann-correlated IOP (IOPg) were mea...

متن کامل

Corneal biomechanical parameters and intraocular pressure: the effect of topical anesthesia

BACKGROUND The intraocular pressures and biomechanical parameters measured by the ocular response analyzer make the analyzer a useful tool for the diagnosis and management of anterior segment disease. This observational study was designed to investigate the effect of topical anesthesia on the parameters measured by the ocular response analyzer: corneal hysteresis, corneal resistance factor, Gol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of glaucoma

دوره 15 5  شماره 

صفحات  -

تاریخ انتشار 2006