Clinical performance of an in-line, ex vivo point-of-care monitor: a multicenter study.

نویسندگان

  • Glenn F Billman
  • Amy B Hughes
  • Golde G Dudell
  • Elizabeth Waldman
  • Lisa M Adcock
  • Dan M Hall
  • Edmund N Orsini
  • Adolph J Koska
  • Linda J Van Marter
  • Neil N Finer
  • Jeff C Kulhavy
  • Ronald D Feld
  • John A Widness
چکیده

BACKGROUND The management of critically ill infants and neonates includes frequent determination of arterial blood gas, electrolyte, and hematocrit values. An objective of attached point-of-care patient monitoring is to provide clinically relevant data without the adverse consequences associated with serial phlebotomy. METHODS We prospectively determined the mean difference (and SD of the difference) from laboratory methods of an in-line, ex vivo monitor, the VIA LVM Blood Gas and Chemistry Monitoring System (VIA LVM Monitor; Metracor Technologies, Inc.), in 100 critically ill neonates and infants at seven children's hospitals. In doing so, we examined monitor stability with continuous use. In vivo patient test results from laboratory benchtop analyzers were compared with those from the VIA LVM Monitor on paired samples. In a separate in vitro comparison, benchtop analyzer and monitor test results were compared on whole-blood split samples. RESULTS A total of 1414 concurrent, paired-sample measurements were obtained. The mean differences (SD of differences) from laboratory methods and r values for the combined data for the VIA LVM Monitor from the seven sites were 0.001 (0.026) and 0.97 for pH, 0.7 (3.6) mmHg and 0.94 for PCO(2), 4.2 (9.6) mmHg and 0.98 for PO(2), 0.0 (2.9) mmol/L and 0.87 for sodium, 0.1 (0.2) mmol/L and 0.96 for potassium, and 0.3% (2.9%) and 0.90 for hematocrit. Performance results were similar among the study sites with increasing time of monitor use and between in vivo paired-sample and in vitro split-sample test results. CONCLUSION The VIA LVM Monitor can be used to assess critically ill neonates and infants.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing Vitamin B12 and Nitrous Oxide Neurotoxicity in Operating Room Staff and other Hospital Staff: A Multicenter Study

Background and purpose: Nitrous oxide (N2O) is an anesthetic widely used in operating rooms. Chronic exposure to N2O causes decrease in mental performance, peripheral neuropathy, and polyneuropathy. The aim of this study was to compare neurological complications caused by N2O exposure between operating room staff and other hospital staff. Materials and methods: In this multicenter cohort study...

متن کامل

Spiritual care by nurses in curative oncology: a national, multicenter, mixed method study

Purpose: To explore the level of and the experiences with spiritual care by nurses in curative cancer care. Methods: In this mixed-method study, nurses were recruited in eight hospitals in The Netherlands. Questionnaire scores were quantitatively analyzed (n=57), and concerned a spirituality and a competence scale, and five questions about spiritual care. Because of data saturation, qualitativ...

متن کامل

Analytical Performance and Quality Control of a Glucose Monitor System

  Background and Objective: The reliability and validity of monitors for self-monitoring of blood glucose are debated. We evaluated the analytical performance of Accu-check Active (Boehringer Mannheim, Roche) which is one of the most commonly used monitors in Iran. Material and Methods: We compared the monitor readings with the reference values by percentage of values within...

متن کامل

Linarin Inhibits the Acetylcholinesterase Activity In-vitro and Ex-vivo

Linarin is a flavone glycoside in the plants Flos chrysanthemi indici, Buddleja officinalis, Cirsium setosum, Mentha arvensis and Buddleja davidii, and has been reported to possess analgesic, antipyretic, anti-inflammatory and neuroprotective activities. In this paper, linarin was investigated for its AChE inhibitory potential both in vitro and ex vivo. Ellman’s colorimetric method was used for...

متن کامل

پایش مدیریت عملکرد آزمایشگاه های بالینی بیمارستانها براساس شاخص‌های تضمین کیفیت در چهارچوب دستورالعمل های سیستم ایزو

Background: Quality assurance is a prevention-oriented system that can be used to improve the quality of care, increase productivity and monitor the performance management in clinical laboratories. ISO 9001: 2000 requirements are a collection of management and technical systems designed to implement quality assurance and monitor performance management in organizations. Methods: A checklist...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 48 11  شماره 

صفحات  -

تاریخ انتشار 2002