Clinical measurement of normal and shear stresses on a trans-tibial stump: characteristics of wave-form shapes during walking.
نویسندگان
چکیده
Stresses on the surface of a stump within a prosthetic socket during walking can potentially traumatize stump tissues. To gain insight into stresses and design parameters that affect them, normal and shear interface stresses were measured on three unilateral trans-tibial amputee subjects during walking trials. During stance phase repeated characteristics in wave-form shapes from different subjects were apparent. They included "loading delays", "high frequency events (HFE's)", "first peaks", "valleys", "second peaks", and "push-off". Characteristics did not necessarily occur at the same time from one step to the next but their timings matched well with events in shank force and moment data which were collected simultaneously. For "plantarflexion" and "dorsiflexion" alignment changes, the above wave-form characteristics were still present but their timings within the stance phase changed. The physical meaning and relevance of the characteristics to stump tissue mechanics are discussed.
منابع مشابه
Normal and shear stresses on a residual limb in a prosthetic socket during ambulation: comparison of finite element results with experimental measurements.
Interface stresses on a below-knee amputee residual limb during the stance phase of gait calculated using an analytical finite element model were compared with experimental interface stress measurements. The model was quasi-static and linear. Qualitatively, shapes of analytical and experimental interface stress waveforms were similar in that they were double-peaked with some distinct features a...
متن کاملInterface shear stresses during ambulation with a below-knee prosthetic limb.
Shear stresses on a residual limb in a prosthetic socket are considered clinically to contribute to tissue breakdown in below-knee amputees. When applied simultaneously with normal stresses, they can cause injury within the skin or can generate an abrasion on the surface. To gain insight into shear stresses and parameters that affect them, interface stresses were recorded on below-knee amputee ...
متن کاملA Patient Specific Finite Element Model of the Residual Bone-Stump-Socket Interaction Validated with High Accuracy Dynamic Radiography Kinematics
A prosthetic socket design and fitting procedure for trans-tibial amputees is an iterative process requiring several visits to a highly skilled prosthetist. Computational modeling can be used to model the socket stump interaction and can assist this iterative fitting process. Dynamic Roentgen Stereophotogrammetric Analysis data was used as boundary conditions to accurately model bone-stump-sock...
متن کاملEffect of a shock-absorbing pylon on transmission of heel strike forces during the gait of people with unilateral trans-tibial amputations: a pilot study.
The primary objective was to test the hypothesis that walking with a shock-absorbing pylon (SAP) decreases the peak magnitude and frequency content of the heel-strike-initiated shock wave transmitted to the stump. The secondary hypotheses were that walking with a SAP decreases the heel-strike transient force between the ground and the foot and increases function as measured by walking velocity ...
متن کاملRelationship between socket pressure and EMG of two muscles in trans-femoral stumps during gait.
The biomechanical interaction between the leg stump and the prosthetic socket is critical in achieving close-to-normal ambulation. Although many investigations have been performed to understand the biomechanics of trans-tibial sockets, few studies have measured the socket interface pressure for transfemoral amputees. Furthermore, no report has examined how the residual muscle activities in the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Prosthetics and orthotics international
دوره 17 1 شماره
صفحات -
تاریخ انتشار 1993