An Automatic , Precision 1 - MHz Digital LCR

نویسنده

  • Kohichi Maeda
چکیده

This new LCR Meter is especially designed for measurements of low-value components in integrated circuits and thinJilm hybrid circuits, as wellas of discrete components. /t uses a four-pair measurement technique to reduce errors caused by stray capacitance, residual inductance, and mutual inductance of the tesf /eads. T N THE MANUFACTURE of integrated circuits, I good process control is essential if yield and reliability are to be maximized. Good process control requires many measurements of parameters on the chip; for example, capacitance versus voltage determines several electrical characteristics of junctions and is an important source of information about the process. Measurement of individual components is also important in the design, testing, and production of thin-film hybrid circuits. Components of interest include resistors, capacitors, inductors, diodes, and transistor junctions. Measurements of low-value components are, of course, subject to errors caused by parasitic reac-tances such as stray capacitance and residual in-ductance. To minimize these errors, the new HP Mo-deI427LA 7-MHz LCR Meter [Fig. r) uses a four-pair measurement technique: the interconnections between the instrument and the circuit under test are four coaxial cables up to one meter long. Also, offset adjustments are used to cancel stray capacitance and conductance or residual inductance and resistance in the test leads between the circuit under test and the inputs to the coaxial cables. The new LCR Meter typically makes five or more readings per second at basic accuracies of 0.1% in ca-pacitance measurements and O.2o/o in inductance, resistance, and conductance measurements. Its read-out is a four-digit light-emitting-diode display that has 90% overrange capability. It displays capaci-tance from 0,001 picofarad to 19.000 nanofarads, in-ductance from 0.1 nanohenry to 1900.0 microhen-ries, resistance from 0.001 ohm to 19.000 kilohms (or conductance from 0.01 micromhos to 190.00 milli-mhos), and dissipation factors of capacitors or induc-tors from 0.0001 to 1.6000. Because it is intended for semiconductor measurements , the test voltages and currents used by the new LCR Meter are low. Capacitance test voltages are 20 mV and 500 mV rms. Inductance test currents are 5 mA to 2 pA.A remotely programmable dc bias source provides 0 to 39.9 volts in 0.1V steps' Options are available for interfacing the LCR Meter to HP calculators and computers' Cover: Model 427 1 A Di gital LCB Meter is well suited for p rod u cti on measu re m e nts of chip capacitors and other components that are used on thinJilm hybrid …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Hoop Residual Stress Variations in the Thickness of Dissimilar Welded Pipes by Using the Lcr Ultrasonic Waves

Original scientific paper Stress measurement by using ultrasonic waves is based on acoustoelasticity law, i. e. the relation between stress and wave velocity in engineering materials. Longitudinal critically refracted (LCR) wave is a popular ultrasonic wave in the ultrasonic stress measurement application. The LCR wave is a bulk longitudinal wave that travels within an effective depth underneat...

متن کامل

Broad Band Dielectric Spectroscopy Using an Open-ended Line

In this work a method of broad band dielectric spectroscopy using an open-ended line is proposed. The mathematical development of this method leads to a transcendental equation on the complex plane that possesses infinite solutions. A numerical procedure is described which is capable of obtaining the solution required avoiding the problem of infinite solutions. The study of this equation sugges...

متن کامل

Coevolution and ratiometric behaviour in metal cation-driven dynamic covalent systems† †Electronic supplementary information (ESI) available. See DOI: 10.1039/c6sc04662b Click here for additional data file.

Instrumentation: NMR spectra were recorded on Bruker Advance 400 (400.14 MHz for 1H and 100.62 MHz for 13C), Bruker Advance III plus 400 (400.34 MHz for 1H and 100.67 MHz for 13C), and Bruker Advance III 600 (600.13 MHz for 1H and 150.90 MHz for 13C) NMR spectrometers. All the collected spectra were referenced on residual solvent signal according to Nudelman and coworkers.[1] Mass spectra were ...

متن کامل

A Microcontroller Based Digital Vector Impedance Meter With Sampling Reduction

Abstract This paper proposed the microcontroller based vector impedance meter, which can be used to measure unidentified impedance of the system. The microcontroller read only four samples from two voltage signals, the first voltage is proportional to the voltage across the impedance while the second voltage is proportional to the current passing through it. A novel algorithm is then used to ge...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006