Comparison of radiation dose to the left anterior descending artery by whole and partial breast irradiation in breast cancer patients

نویسندگان

  • Kazuhiko Sato
  • Yoshio Mizuno
  • Hiromi Fuchikami
  • Masahiro Kato
  • Takahiro Shimo
  • Jun Kubota
  • Naoko Takeda
  • Yuko Inoue
  • Hiroshi Seto
  • Tomohiko Okawa
چکیده

PURPOSE Breast conserving surgery (BCS) followed by whole breast irradiation (WBI) is the standard of care for breast cancer patients. However, there is a risk of coronary events with WBI therapy. In this study, we compared the radiation dose in the left anterior descending artery (LAD) in patients receiving partial breast irradiation (PBI) with WBI. MATERIAL AND METHODS We evaluated consecutive patients who underwent adjuvant radiotherapy after BCS between October 2008 and July 2014. Whole breast irradiation patients received 50 Gy in fractions of 2 Gy to the entire breast. Partial breast irradiation was performed using multicatheter brachytherapy at a dose of 32 Gy in eight fractions. The mean and maximal cumulative doses to LAD were calculated. The radiotherapeutic biologically effective dose of PBI was adjusted to WBI, and radiation techniques were compared. RESULTS Of 379 consecutive patients with 383 lesions receiving radiotherapy (151 WBI and 232 PBI lesions), 82 WBI and 100 PBI patients were analyzed. In WBI patients, the mean and maximal cumulative doses for left-sided breast cancer (2.13 ± 0.11 and 8.19 ± 1.21 Gy, respectively) were significantly higher than those for right-sided (0.37 ± 0.02 and 0.56 ± 0.03 Gy, respectively; p < 0.0001). In PBI patients with left-sided breast cancer, the doses for tumors in inner quadrants or central location (2.54 ± 0.21 and 4.43 ± 0.38 Gy, respectively) were significantly elevated compared to outer quadrants (1.02 ± 0.17 and 2.10 ± 0.29 Gy, respectively; p < 0.0001). After the adjustment, the doses in PBI patients were significantly reduced in patients with tumors only in outer quadrants (1.12 ± 0.20 and 2.43 ± 0.37 Gy, respectively; p = 0.0001). CONCLUSIONS Tumor control and dose to LAD should be considered during treatment since PBI may reduce the risk of coronary artery disease especially in patients with lateral tumors in the left breast.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of different treatment planning techniques on radiation doses to the heart, left anterior descending coronary artery and left lung in the radiotherapy of left-sided breast cancer patients

Background: Breast-conserving surgery (BCS) followed by radiotherapy (RT) is the standard of care for women with breast cancer. Evidence shows that RT dose to the heart can result in ischemic heart disease. In this study we compared 3 different RT techniques were for heart, left anterior descending coronary artery (LAD) and lung doses in left breast cancer patients after breast-conserving surge...

متن کامل

Dosimetric comparison of whole breast radiotherapy using field in field and conformal radiotherapy techniques in early stage breast cancer

Background: We aimed to compare field-in-field technique (FIF) with conformal tangential field radiotherapy (CRT) in terms of dosimetric benefits for early stage breast cancer radiotherapy. Materials and Methods: Twenty consecutive left-side breast cancer patients who underwent breast-conserving surgery were included to the study. For each patient, two different treatment plans were cr...

متن کامل

A Comparative Study of 3-D Conformal Radiotherapy Treatment Plans with and Without Deep Inspiration Breath-Hold Technique for Left-Sided Breast Cancer

Introduction: The rate of cardiac diseases have increased among patients who underwent radiotherapy for left-sided breast cancer. The study’s aim was evaluate the dose to organs at risk in free-breathing 3-dimensional conformal (FB-3DCRT) against 3-dimensional conformal deep inspiration breath-hold (3DCRT-DIBH) in patients with left-sided breast cancer. Ma...

متن کامل

Dosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions

Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...

متن کامل

Dose-volume Analysis of Heart and Lung during 3D planning of Tangential Breast Cancer Irradiation

Background: Breast cancer is becoming more frequently diagnosed at early stages with improved long term outcomes. Radiation-related heart disease and lung cancer can occur following radiotherapy for breast cancer. The aim of this study was to evaluate some dosimetric parameters of heart and lung during whole breast radiotherapy. Methods:Twenty five consecutive...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2015