Simultaneous determination of gliquidone, fexofenadine, buclizine, and levocetirizine in dosage formulation and human serum by RP-HPLC.
نویسندگان
چکیده
In the present paper, a simultaneous method has been developed and validated for estimation of gliquidone in the presence of H(1)-receptor antagonists (fexofenadine hydrochloride, buclizine hydrochloride, and levocetirizine dihydrochloride) using reversed-phase high-performance liquid chromatographic technique. A good chromatographic separation between these drugs was achieved using a mobile phase containing methanol-water (80:20 v/v) at pH 3.5 with a flow rate of 1.0 mL/min; and detection was performed at 230 nm with a UV detector. Validation of the method was performed in terms of linearity, accuracy, precision, and limit of detection and quantification. The linearity of the calibration curves for gliquidone, fexofenadine hydrochloride, buclizine hydrochloride, and levocetirizine dihydrochloride were found to be 0.338-50 microg/mL (r = 0.9964), 5-50 microg/mL (r = 0.9956), 0.325-50 microg/mL (r = 0.9967), and 0.553-50 microg/mL (r = 0.9950), respectively. There was no significant difference between the amount of drug spiked in serum and the amount recovered, and serum did not interfere in simultaneous estimation. Thus, the proposed method is suitable for the simultaneous analysis of active ingredients in tablet dosage forms and human serum.
منابع مشابه
Simultaneous determination of gliquidone, pioglitazone hydrochloride, and verapamil in formulation and human serum by RP-HPLC.
In the present study, a reverse-phase high performance liquid chromatography method was developed, validated and applied for the simultaneous determination of gliquidone, pioglitazone hydrochloride and verapamil in tablets and human serum. Chromatographic separation was achieved on a C18 column (5 μm, 25 × 0.46 cm) with a mobile phase consisting of methanol-water-acetonitrile (80:10:10 v/v/v) w...
متن کاملSimultaneous Determination of Amlodipine with H1-Receptor Antagonists by Reversed Phase High Performance Liquid Chromatography and Application to Interaction Studies
A rapid, fast and precise method has been developed and validated for the simultaneous determination of amlodipine with H1-receptor antagonists (cetirizine, fexofenadine, and buclizine) from dosage forms. The chromatography was performed on a Purospher Star, C18 (5 μm, 250 × 4.6 mm) column using acetonitrile: buffer (0.01 mM) (40:60, v/v, pH adjusted to 3.0), as a mobile phase. The mobile phase...
متن کاملSimultaneous Determination of Montelukast Sodium and Fexofenadine Hydrochloride in Combined Dosage Form by Using RP-HPLC Method
A simple, accurate, economical and reproducible reverse phase high performance liquid chromatographic (RP-HPLC) method was developed and validated for the determination of montelukast sodium and fexofenadine hydrochloride in bulk and pharmaceutical formulations. The separation was achieved on a phenomenex C column (150 × 4.6 mm i.d, particle size of 5μ) using a mixture of 0.1M potassium dihydro...
متن کاملSimultaneous RP-HPLC and UV Spectroscopic Method Development and Validation for Estimation of Ibandronate Sodium in Bulk and Pharmaceutical Dosage Form
The present study describes a simple, accurate, precise and cost effective UV-Vis Spectroscopic and RP-HPLC method for the estimation of Ibandronate sodium (IBN). The determination of Ibandronate sodium (IBN) was performed by both UV and RP-HPLC method using 215 nm as the determination wavelength. The drug was dissolved in NaOH solution (0.1N NaOH) for estimation in UV and in distilled water fo...
متن کاملA new stability - indicating RP - HPLC method for the simultaneous determination of fexofenadine hydrochloride and montelukast in combined dosage form
A new stability-indicating RP-HPLC method was developed for the simultaneous determination of fexofenadine hydrochloride and montelukast in combined dosage form, using a Aligent, Zorbax (Make: 150 mmx4.6 mm I.D; particle size 5μm and a mobile phase composed of phospahte buffer (pH 4.0): Acetonitile (60:40 v/v) at a flow rate of 1.0mL/min. The retention times of fexofenadine hydrochloride and mo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of chromatographic science
دوره 48 5 شماره
صفحات -
تاریخ انتشار 2010