FSI analysis of a human trachea before and after prosthesis implantation.
نویسندگان
چکیده
In this work we analyzed the response of a stenotic trachea after a stent implantation. An endotracheal stent is the common treatment for tracheal diseases such as stenosis, chronic cough, or dispnoea episodes. Medical treatment and surgical techniques are still challenging due to the difficulties in overcoming potential complications after prosthesis implantation. A finite element model of a diseased and stented trachea was developed starting from a patient specific computerized tomography (CT) scan. The tracheal wall was modeled as a fiber reinforced hyperelastic material in which we modeled the anisotropy due to the orientation of the collagen fibers. Deformations of the tracheal cartilage rings and of the muscular membrane, as well as the maximum principal stresses, are analyzed using a fluid solid interaction (FSI) approach. For this reason, as boundary conditions, impedance-based pressure waveforms were computed modeling the nonreconstructed vessels as a binary fractal network. The results showed that the presence of the stent prevents tracheal muscle deflections and indicated a local recirculatory flow on the stent top surface which may play a role in the process of mucous accumulation. The present work gives new insight into clinical procedures, predicting their mechanical consequences. This tool could be used in the future as preoperative planning software to help the thoracic surgeons in deciding the optimal prosthesis type as well as its size and positioning.
منابع مشابه
Patient-specific models of human trachea to predict mechanical consequences of endoprosthesis implantation.
Nowadays, interventions associated with the implantation of tracheal prostheses in patients with airway pathologies are very common. This surgery may promote problems such as migration of the prosthesis, development of granulation tissue at the edges of the stent with overgrowth of the tracheal lumen or accumulation of secretions inside the prosthesis. Among the movements that the trachea carri...
متن کاملBioengineered trachea using autologous chondrocytes for regeneration of tracheal cartilage in a rabbit model.
OBJECTIVES/HYPOTHESIS In this study, a bioengineered trachea composed of autologous chondrocytes was developed, and its effect on cartilaginous regeneration was evaluated by implantation into tracheal defects in rabbits. STUDY DESIGN Prospective controlled trial in an animal model. METHODS The tracheal prosthesis used in this study was composed of polypropylene (the frame) and collagen spon...
متن کاملDevelopment of surgical protocol for implantation of tracheal prostheses in sheep.
This article documents experiments performed in ewes to design an artificial larynx. The artificial larynx is composed of a hollow, porous tube that elongates the trachea and is capped with a valve that acts as a laryngeal sphincter. Through an industrial collaboration, our team developed a porous biomaterial that can be colonized by cervical tissues. This biomaterial has been used in animals t...
متن کاملFSI Analysis of a healthy and a stenotic human trachea under impedance-based boundary conditions.
In this work, a fluid-solid interaction (FSI) analysis of a healthy and a stenotic human trachea was studied to evaluate flow patterns, wall stresses, and deformations under physiological and pathological conditions. The two analyzed tracheal geometries, which include the first bifurcation after the carina, were obtained from computed tomography images of healthy and diseased patients, respecti...
متن کاملRadial Head Prosthesis Removal:a Retrospective Case Series of 14 Patients
Background: The purpose of this study was to report the preoperative complaints and postoperative outcome of patients after removal of the radial head prosthesis. Methods: This is a retrospective review of 14 adult patients (6 females and 8 males) from 2007 to 2011, who underwent radial head prosthesis removal by three surgeons. The average time between implantation and removal was 23 month...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of biomechanical engineering
دوره 133 7 شماره
صفحات -
تاریخ انتشار 2011