5-Year Outcomes After Transcatheter Aortic Valve Implantation With CoreValve Prosthesis.
نویسندگان
چکیده
OBJECTIVES The purpose of this analysis was to assess 5-year outcomes of transcatheter aortic valve implantation (TAVI) using the current technology of the self-expanding CoreValve prosthesis (Medtronic Inc., Minneapolis, Minnesota). BACKGROUND There is a paucity of evidence on long-term durability of currently available transcatheter heart valves. METHODS Starting in June 2007, all consecutive patients with severe aortic stenosis undergoing TAVI with the third-generation 18-F CoreValve device in 8 Italian centers were prospectively included in the ClinicalService Project. For the purposes of this study, we included only consecutive patients with 5-year follow-up data available (n = 353) treated from June 2007 to August 2009. All outcomes were reported according to VARC (Valve Academic Research Consortium)-1 criteria. RESULTS All-cause mortality rates at 1, 2, 3, 4, and 5 years were 21%, 29%, 38%, 48%, and 55.0%, respectively. Cardiovascular mortality rates at 1, 2, 3, 4, and 5 years were 10%, 14%, 19%, 23%, and 28.0%, respectively. The overall neurological event rate at 5 years was 7.5%, of which more than two-thirds occurred early after the procedure. During follow-up, there were 241 rehospitalizations for cardiovascular reasons in 164 (46%) patients. Among all rehospitalizations, acute heart failure was the most frequently reported (42.7%), followed by requirement of permanent pacemaker implantation (17.4%). On echocardiography, mean transaortic gradients decreased from 55.6 ± 16.8 mm Hg (pre-TAVI) to 12.8 ± 10.9 mm Hg (5-year post-TAVI) (p < 0.001). Late prosthesis failure occurred in 5 cases (1.4%); among these, redo TAVI was successfully carried out in 2 patients (0.6%) presenting with symptomatic prosthesis restenosis. The remaining 3 cases of prosthesis failure did not undergo further invasive interventions. Ten patients (2.8%) showed late mild stenosis with a mean transaortic gradient ranging from 20 to 40 mm Hg. No other cases of structural or nonstructural valvular deterioration were observed. Valve thrombosis or late valve embolization were not reported. CONCLUSIONS TAVI with the currently adopted CoreValve generation was associated with sustained clinical outcomes up to 5-year follow-up, with a low rate (1.4%) of significant prosthetic valve degeneration. The procedure appears to be an adequate and lasting resolution of aortic stenosis in selected high-risk patients.
منابع مشابه
Incidence and management of CoreValve dislocation during transcatheter aortic valve implantation.
BACKGROUND Transcatheter aortic valve implantation is a highly specialized technique offering a new therapeutic option to patients at high risk for conventional surgery. Complications associated with this catheter procedure differ from complications after surgical aortic valve replacement. This is to report incidence, management, and impact on morbidity and mortality of CoreValve dislocation du...
متن کاملSurgical Bailout Therapy after Implantation of a Medtronic CoreValve Bioprosthesis
Moderate-to-severe paraprosthesic leak causing hemodynamic deterioration and left ventricular remodeling can occur after transcatheter aortic valve implantation (TAVI). We present the case of a 75-year-old woman who underwent TAVI with a 26 mm CoreValve prosthesis complicated with an acute left ventricle dilatation due to a severe paravalvular leak. Patient was unresponsive to elective balloon ...
متن کاملCause of complete atrioventricular block after percutaneous aortic valve implantation: insights from a necropsy study.
Transcatheter aortic valve implantation is being established as an alternative treatment for some patients with symptomatic severe aortic stenosis who are not considered suitable for surgical aortic valve replacement because of prohibitive surgical risk.1–3 One of the potential complications is complete atrioventricular block requiring definitive pacemaker implantation. This complication occurs...
متن کاملTranscatheter aortic valve-in-valve implantation of a CoreValve in a JenaValve prosthesis: a case report
BACKGROUND Transcatheter aortic valve implantation has become an accepted treatment modality for inoperable or high-risk surgical patients with symptomatic severe aortic stenosis. CASE PRESENTATION We report the case of a 70-year-old white man who was treated for severe symptomatic aortic regurgitation using transcatheter aortic valve implantation from the apical approach. Because of recurren...
متن کاملTranscatheter aortic valve implantation: 3-year outcomes of self-expanding CoreValve prosthesis.
AIMS The paucity of evidences about the long-term durability of currently available transcatheter prostheses is one of the main issues of transcatheter aortic valve implantation (TAVI). We sought to assess 3-year clinical and echocardiographic outcomes of patients undergoing TAVI with the third generation CoreValve prosthesis (Medtronic Incorporation, MN, USA). METHODS AND RESULTS From the It...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- JACC. Cardiovascular interventions
دوره 8 8 شماره
صفحات -
تاریخ انتشار 2015