A submersible battery-powered flow injection (FI) sensor for the determination of nitrate in estuarine and coastal waters

نویسندگان

  • Anthony R. J. David
  • Trevor McCormack
  • Paul J. Worsfold
چکیده

The design, construction and performance of a remotely deployed submersible flow injection-based nutrient (total oxidized nitrogen) sensor are described. The sensor featured a custom-built microcomputer and a solid-state, flow-through spectrophotometric detector, and the derivatization chemistry was based on in-line copper-cadmium reduction of nitrate to nitrite, and diazotization with N1NED and sulphanilamide. The limit of detection was 0.0014 mg l(-1) NO3-N and the linear range was 0.0014- 0.77 mg l(-1) with a 260 microl sample volume and a 20 mm path length flow cell. Results from submersed deployments in the Tamar estuary and North Sea are also reported.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A portable battery-powered flow injection monitor for the in situ analysis of nitrate in natural waters

The design and performance of a portable, automated flow injection (FI)-based photometric monitor are described. The system is controlled by an in-house microcomputer system that enables the monitor (including a solid state detector) to operate from a 12 V battery supply. The monitor uses the cadmium reduction/diazotization method to analyse for nitrate with a linear range of 0 to 12 mg l(-1) a...

متن کامل

A flow injection-fluorometric method for the determination of ammonium in fresh and saline waters with a view to in situ analyses.

A version of the orthophthaldialdehyde-fluorescence ammonium determination for flow injection analysis (FIA) is presented here, with a view to its use for in situ, low-power consumption systems. Thus, the reaction temperature was limited to 30 degrees C and FIA was used in stop-flow mode (3 min stop). The calibration is linear up to 50 mumol l-1, but concentrations up to 100 mumol l-1 can be me...

متن کامل

Determination of Nitrite and Nitrate in Natural Waters Using Flow Injection with Spectrophotometric Detection

A simple and sensitive flow injection spectrophotometric method is reported for the room temperature determination of nitrite and nitrate based on the Griess reaction and a copperised cadmium column for reduction of nitrate. Calibration graphs were linear over the range 2 – 1000 μg N L (R = 0.9997 and 0.9999, n = 9) with a limit of detection (3 s.d.) of 1.0 μg N L and relative standard deviatio...

متن کامل

Occurrence of Pathogenic Vibrios in Coastal Areas of Golestan Province in Iran

  This study was carried out to investigate the occurrence of potentially pathogenic species of vibrio in sea water and estuarine environments of the Caspian Sea in the Golestan province of Iran. A total of 127 water samples from coastal waters as well as from river and estuaries were collected and analyzed by culture, during April and September 2001. Following prompt centrifugation, the resusp...

متن کامل

Regulation of estuarine primary production by watershed rainfall and river flow

Enhanced phytoplankton production and algal blooms, symptoms of eutrophication, are frequently caused by elevated nutrient loading, usually a s nitrogen, to coastal waters. This nitrogen is derived primarily from anthropogenic sources (urban, industrial, and agricultural) but is delivered to coastal waters through meteorological and hydrological means. We utilized a 4 yr monthly data set to inv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of Automated Methods and Management in Chemistry

دوره 21  شماره 

صفحات  -