Early and mid-term outcome in terms of functional and hemodynamic performance of the st. Jude regent 19-mm aortic mechanical prosthesis versus 19-mm carpentier edwards aortic biological prosthesis

نویسندگان

  • Edvin Prifti
  • Massimo Bonacchi
  • Fadil Ademaj
  • Gabriele Giunti
  • Giampiero Esposito
  • Arben Baboci
  • Gani Bajraktari
  • Altin Veshti
  • Aurel Demiraj
  • Vittorio Vanini
چکیده

BACKGROUND The aim of the present study is to compare the early and mid-term clinical and hemodynamic results of the aortic valve replacement (AVR) with a St Jude Medical Regent 19-mm prosthesis (SJMR-19) versus Carpentied-Edwars bovine pericardial 19-mm valve (CE-19). METHODS Between January 2002 and January 2012, 265 patients (Group I) and 58 patients (Group II) with underwent AVR with a SJMR-19 and CE-19 respectively. There were no significant differences between groups regarding the demographic and preoperative echocardiographic data. Thirty-six patients in Group I and 4 in Group II required annulus enlargement in association or not with septal myectomy. The mean follow-up was 34 ± 18.5 months (range 5-60 months). RESULTS There were 14 (5.3 %) hospital deaths in Group I versus 4 (6.8 %) in Group II (p = 0.86). The multivariate logistic regression analysis identified the LVEF ≤ 35 % (p = 0.001), combined operation (p = 0.0005), CPB (p = 0.033), age (p = 0.011), annulus enlargement (p = 0.0009), reoperation (p = 0.039) and chronic renal failure (p = 0.011) as strong predictors for early postoperative death. Within 1 year after surgery peak pulmonary artery pressure, interventricular septal and left ventricular posterior wall thickness decreased significantly in both groups. The M-TPG was 15.7 ± 6.5 mmHg in Group I versus 17 ± 7 mmHg in Group II (p = 0.19). The multivariate regression analysis revealed the annulus enlargement (p = 0.018), small EOAi (p = 0.00004), postoperative LVMi (p = 0.0001) and BSA (p = 0.019) as strong predictors for higher M-TPG. The postoperative LVMi was 119 ± 22.5 gm/m(2) in Group I and 122 ± 22 gm/m(2) in Group II (p = 0.37), significantly lower than the respective preoperative values 162.5 ± 34 gm/m(2) (Group I) and 168 ± 30 gm/m(2) (Group II). The actuarial survival and cumulative free-reoperation actuarial survival at 5 years follow-up were 96.7 and 94.5 % respectively in Group I and 97 and 91 % in Group II.. There were non significant differences between groups regarding the actuarial survival and cumulative free-reoperation survival. The Cox model identified the older age (p = 0.022), LVEF ≤ 35 % (p = 0.009), reoperation (p = 0.018), combined surgery (p = 0.00075) and annulus enlargement (p = 0.033) as strong predictors for poor actuarial free-reoperation survival. CONCLUSIONS Both the SJMR-19 and CE-19 offers excellent postoperative clinical and hemodynamic outcome in patients with small aortic annulus. The LV hypertrophy and transvalvular gradients are reduced significantly indenpendently of the employed SJMR-19 or CE-19 prosthesis. Our data support recent suggestions that small valve size does not influence intermediate free-reoperation survival. The CE-19 is an excellent alternative to SJMR-19 in old patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Double Valve Replacement (Mitral and Aortic) for Rheumatic Heart Disease: A 20-year experience with 300 patients.

Introduction: Rheumatic heart disease still remains one of the leading causes of congestive heart failure and death owing to valvular pathologies, in developing countries. Valve replacement still remains the treatment of choice in such patients.The aim of this study wasto analyze the postoperative outcome of  double valve replacement (Mitral and Aortic ) in patients of rheumatic heart disease. ...

متن کامل

On-X versus St Jude Medical Regent mechanical aortic valve prostheses: early haemodynamics

OBJECTIVE We aimed to compare the early haemodynamic data of the On-X and St Jude Medical (SJM) Regent bileaflet mechanical prostheses in the aortic position. METHODS A retrospective study was performed using data collected prospectively for a national database. Thirty-three patients who had aortic On-X valve (On-X group) and 33 matched patients who had aortic SJM Regent valve (SJM group) wer...

متن کامل

The Scandinavian multicenter hemodynamic evaluation of the SJM Regent aortic valve

BACKGROUND 112 patients who received small and medium sized St. Jude Regent heart valves (19-25 mm) at 7 Scandinavian centers were studied between January 2003 and February 2005 to obtain non-invasive data regarding the hemodynamic performance at rest and during Dobutamine stress echocardiography (DSE) testing one year after surgery. MATERIAL AND METHODS 46 woman and 66 men, aged 61.8 ± 9.7 (...

متن کامل

Application of Regent mechanical valve in patients with small aortic annulus: 3-year follow-up

BACKGROUND Aortic valve replacement (AVR) with a small aortic annulus is always challenging for the cardiac surgeon. In this study, we sought to evaluate the midterm performance of implantation with a 17-mm or 19-mm St. Jude Medical Regent (SJM Regent) mechanical valve in retrospective consecutive cohort of patients with small aortic annulus (diameter ≤ 19 mm). METHODS From January 2008 to Ap...

متن کامل

Doppler derived gradient of St. Jude mechanical prosthesis, early postoperative assessment.

OBJECTIVE To determine the doppler derived mean gradients of St Jude mechanical prosthesis in early postoperative period in patients undergoing valve replacement at a tertiary care cardiac centre. METHODS Medical records of 190 consecutive patients who underwent 233 mitral, aortic or dual (mitral and aortic) valve replacement by St Jude bileaflet mechanical prosthesis at Tabba Heart Institute...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015