A New Method to Improve the Sensitivity of Leak Detection in Self-Contained Fluid-Filled Cables

نویسندگان

  • L. Hao
  • P. L. Lewin
  • S. G. Swingler
چکیده

The condition of a 400 kV underground FF cable route within the National Grid transmission network has been monitored by Drallim pressure, temperature and load current measurement system. These three measured variables are used as parameters to describe the condition of the cable system. In the regression analysis the temperature and load current of the cable circuit are used as independent variables and the pressure within cables is the dependent variable to be predicted. As a supervised learning algorithm, the SVR requires data with known attributes as training samples in the learning process and can be used to identify unknown data or predict future trends.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coupled Vibration of Partially Fluid-Filled Laminated Composite Cylindrical Shells

In this study, the free vibration of partially fluid-filled laminated composite circular cylindrical shell with arbitrary boundary conditions has been investigated by using Rayleigh-Ritz method. The analysis has been carried out with strain-displacement relations based on Love’s thin shell theory and the contained fluid is assumed irrotational, incompressible and inviscid. After determining the...

متن کامل

INVERSE FREQUENCY RESPONSE ANALYSIS FOR PIPELINES LEAK DETECTION USING THE PARTICLE SWARM OPTIMIZATION

Inverse Transient Analysis (ITA) is a powerful approach for leak detection of pipelines. When the pipe transient flow is analyzed in frequency domain the ITA is called Inverse Frequency Response Analysis (IFRA). To implement an IFRA for leak detection, a transient state is initiated in the pipe by fast closure of the downstream end valve. Then, the pressure time history at the valve location is...

متن کامل

Calibration curves for on-line leakage detection using radiotracer injection method

One of the most important requirements for industrial pipelines is the leakage detection. In this paper, detection of leak and determination of its amount using radioactive tracer injection method has been simulated by Monte Carlo MCNP code. The detector array included two NaI (Tl) detectors which were located before and after the considered position, measure emitted gamma from radioactive trac...

متن کامل

Statistical Review of Major Standpoints in Hydraulic Transient-Based Leak Detection

Today, pipe systems are the most common facilities to convey various fluids from one place to another. In such facilities faults like leaks lead to advert consequences such as economic losses and social health threats. The fact that early detection of leaks can play a prominent role in reducing the amount of these undesired impacts has absorbed noticeable attention from researchers to this fiel...

متن کامل

Transient Measurement Site Design in pipe networks using the Decision Table Method (DTM)

The accuracy of leak detection and calibration of pipe networks by means of the inverse transient analysis (ITA) is highly affected by the number and location of the measurement sites. This study introduces a conceptual decision-making model, the Decision Table Method (DTM), for the measurement site design of pipe networks with the aim of inverse transient analysis. Through the Decision Table M...