An inductively coupled plasma carbon emission detector for aqueous carbohydrate separations by liquid chromatography.

نویسندگان

  • H L Peters
  • K E Levine
  • B T Jones
چکیده

An inductively coupled plasma atomic emission spectrometer is used to detect carbon-containing compounds following separation by high-performance liquid chromatography. A calcium form ligand exchange column with distilled and deionized water as the mobile phase is used to separate carbohydrates. The eluting species are detected by monitoring the carbon atomic emission line at 193.09 nm. The mass detection limits using a photomultiplier tube for sucrose and glucose are 50 ng, while that for fructose is 60 ng. The carbon emission detector should provide the same detection limit for any compound with a similar mass percent of carbon, whether or not the compound exhibits appreciable absorption characteristics. While the carbon emission detector will universally detect any organic compound, it will discriminate against species with high molar absorptivity that may be present at low concentration. Such species may act as interferences in chromatograms generated with conventional UV-visible absorption detectors. To demonstrate the utility of the carbon emission detector, three sugars (glucose, fructose, sucrose) are determined in apple, crangrape, and orange juice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Non-Metal Emission Detector for HPLC

A liquid chromatography system with an inductively coupled plasma detector is used to prepare a single calibration curve that is useful for multiple analytes. The detector monitors the atomic emission from carbon at 193.09 nm. Hence the analytes need not exhibit appreciable molar absorptivity or native fluorescence. Since the carbon signal is independent of molecular structure, the sensitivitie...

متن کامل

Screening and Optimization of Microextraction of Pb(II) by Inductively Coupled Plasma-Atomic Emission Using Response Surface Methodology

Dispersive liquid–liquid microextraction (DLLME) combined with inductively coupled plasma-atomic emission spectrometry (ICP-AES) was applied for the determination of lead in different environmental water samples. Ammonium pyrrolidine dithiocarbamate (APDC), chloroform and ethanol were used as chelating agent, extraction solvent and disperser solvent, respectively. The effective parameters, such...

متن کامل

Organic matter from biofilter nitrification by high performance size exclusion chromatography and fluorescence excitation-emission matrix

A combination of high performance size exclusion chromatography with organic carbon detector and ultraviolet detector coupled with peak-fitting technique and fluorescence excitation-emission matrix spectrometry applied fluorescence regional integration method was conducted to determine the characteristics of organic matter during nitrification. The batch scale of bionet nitrification without or...

متن کامل

Selective Separation and Preconcentration of trace Amounts of Gallium in Water and Rice Samples using Cloud Point Extraction and Determination by Inductively Coupled Plasma-Atomic Emission Spectrometry

In the present study a cloud-point extraction process using non-ionic surfactant Triton X-114 for selective extraction of gallium from aqueous solutions was developed. The method is based on the complex formation of Ga (III) with N, N′ -bis (salycilidene)-1, 2-phenylenediamine (salophen) as a chelating agent in buffer media of pH 5. After phase separation and dilution of the surfactant-rich pha...

متن کامل

A Comparison of GC-ICP-MS and HPLC-ICP-MS for the Analysis of Organotin Compounds Application

An inductively coupled plasma mass spectrometer (ICP-MS) was used as a detector for gas chromatography (GC) and high performance liquid chromatography (HPLC) analysis of organotin compounds. ICP-MS is a highly sensitive detector with detection limits in the pg ng range, as well as enabling calibration by isotope dilution mass spectrometry (IDMS). Calibrating using isotopically labeled organotin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 73 3  شماره 

صفحات  -

تاریخ انتشار 2001