On the estimate of the two dominant axes of the knee using an instrumented spatial linkage.

نویسنده

  • Gianluca Gatti
چکیده

This article presents the validation of a technique to assess the appropriateness of a 2 degree-of-freedom model for the human knee, and, in which case, the dominant axes of flexion/extension and internal/external longitudinal rotation are estimated. The technique relies on the use of an instrumented spatial linkage for the accurate detection of passive knee kinematics, and it is based on the assumption that points on the longitudinal rotation axis describe nearly circular and planar trajectories, whereas the flexion/extension axis is perpendicular to those trajectories through their centers of rotation. By manually enforcing a tibia rotation while bending the knee in flexion, a standard optimization algorithm is used to estimate the approximate axis of longitudinal rotation, and the axis of flexion is estimated consequently. The proposed technique is validated through simulated data and experimentally applied on a 2 degree-of-freedom mechanical joint. A procedure is proposed to verify the fixed axes assumption for the knee model. The suggested methodology could be possibly valuable in understanding knee kinematics, and in particular for the design and implant of customized hinged external fixators, which have shown to be effective in knee dislocation treatment and rehabilitation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimized design of an instrumented spatial linkage that minimizes errors in locating the rotational axes of the tibiofemoral joint: a computational analysis.

An accurate method to locate of the flexion-extension (F-E) axis and longitudinal rotation (LR) axis of the tibiofemoral joint is required to accurately characterize tibiofemoral kinematics. A method was recently developed to locate these axes using an instrumented spatial linkage (ISL) (2012, "On the Estimate of the Two Dominant Axes of the Knee Using an Instrumented Spatial Linkage," J. Appl....

متن کامل

MOLECULAR STUDY OF PKD1 & PKD2 GENES BY LINKAGE ANALYSIS AND DETERMINING THE GENOTYPE/PHENOTYPE CORRELATIONS IN SEVERAL IRANIAN FAMILIES WITH AUTOSOMAL DOMINANT POLYCYSTIC KIDNEY DISEASE

 ABSTRACT Background: Autosomal dominant polycystic kidney disease (ADPKD) is an inherited disorder with genetic heterogeneity. Up to three loci are involved in this disease, PKDI on chromosome 16p13.3, PKD2 on 4q21, and a third locus of unknown location. Methods: Here we report the first molecular genetic study of ADPKD and the existence oflocus heterogeneity for ADPKD in the Iranian populatio...

متن کامل

Design, calibration and validation of a novel 3D printed instrumented spatial linkage that measures changes in the rotational axes of the tibiofemoral joint.

An accurate axis-finding technique is required to measure any changes from normal caused by total knee arthroplasty in the flexion-extension (F-E) and longitudinal rotation (LR) axes of the tibiofemoral joint. In a previous paper, we computationally determined how best to design and use an instrumented spatial linkage (ISL) to locate the F-E and LR axes such that rotational and translational er...

متن کامل

Sensorless Speed Control of Switched Reluctance Motor Drive Using the Binary Observer with Online Flux-Linkage Estimation

An adaptive online flux-linkage estimation method for the sensorless control of switched reluctance motor (SRM) drive is presented in this paper. Sensorless operation is achieved through a binary observer based algorithm. In order to avoid using the look up tables of motor characteristics, which makes the system, depends on motor parameters, an adaptive identification algorithm is used to estim...

متن کامل

Choosing the Best Hierarchical Clustering Technique Based on Principal Components Analysis for Suspended Sediment Load Estimation

1- INTRODUCTION The assessment of watershed sediment load is necessary for controling soil erosion and reducing the potential of sediment production. Different estimates of sediment amounts along with the lack of long-term measurements limits the accessibility to reliable data series of erosion rate and sediment yield. Therefore, the observed data of suspended sediment load could be used to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of applied biomechanics

دوره 28 2  شماره 

صفحات  -

تاریخ انتشار 2012