Bacterial contamination of anesthesia machines’ internal breathing-circuit-systems

نویسندگان

  • Verena Spertini
  • Livia Borsoi
  • Jutta Berger
  • Alexander Blacky
  • Magda Dieb-Elschahawi
  • Ojan Assadian
چکیده

BACKGROUND Bacterial contamination of anesthesia breathing machines and their potential hazard for pulmonary infection and cross-infection among anesthetized patients has been an infection control issue since the 1950s. Disposable equipment and bacterial filters have been introduced to minimize this risk. However, the machines' internal breathing-circuit-system has been considered to be free of micro-organisms without providing adequate data supporting this view. The aim of the study was to investigate if any micro-organisms can be yielded from used internal machines' breathing-circuit-system. Based on such results objective reprocessing intervals could be defined. METHODS The internal parts of 40 anesthesia machines' breathing-circuit-system were investigated. Chi-square test and logistic regression analysis were performed. An on-site process observation of the re-processing sequence was conducted. RESULTS Bacterial growth was found in 17 of 40 machines (43%). No significant difference was ascertained between the contamination and the processing intervals. The most common contaminants retrieved were coagulase negative Staphylococci, aerobe spore forming bacteria and Micrococcus species. In one breathing-circuit-system, Escherichia coli, and in one further Staphylococcus aureus were yielded. CONCLUSION Considering the availability of bacterial filters installed on the outlet of the breathing-circuit-systems, the type of bacteria retrieved and the on-site process observation, we conclude that the contamination found is best explained by a lack of adherence to hygienic measures during and after re-processing of the internal breathing-circuit-system. These results support an extension of the re-processing interval of the anesthesia apparatus longer than the manufacturer's recommendation of one week. However, the importance of adherence to standard hygienic measures during re-processing needs to be emphasized.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

To reuse your circuit: The HME debate, AANA Journal, October 1999

have been used for more than 30 years for heat and moisture retention during general anesthesia. Studies about bacteriostatic vs nonbacteriostatic HMEs (BHMEs/ NHMEs) have been conducted to assess their role in preventing bacterial transmission to the anesthesia breathing circuit; none have been done on anesthetized patients in the operating room. The present study adds to existing knowledge ab...

متن کامل

Sterilization versus disinfection of anesthesia breathing circuits: safety and economic considerations.

Previous studies In 1977, du Moulin and Saubermann compared the bacterial contamination of the anesthesia machine to two groups of patients: one group had upper respiratory tracts colonized with gram negative bacilli and another group had normal upper respiratory tract flora. 4 They found no significant difference between the organisms cultured from the inspiratory and expiratory tubing used by...

متن کامل

Functional characteristics of anesthesia machines with circle breathing system

Presently, the majority of anesthesia machines or workstations are ventilators that incorporate a classic circle system/circuit with a CO2 absorber that allows rebreathing of exhaled gases. The performance characteristics of these machines are related to the physical structure of the breathing circuit. Limitations related to the classical circle breathing circuit are progressively disappearing ...

متن کامل

بررسی آلودگی باکتریال در مدار تنفسی ماشین های بیهوشی

Introduction : Hospital infections are one of the important reasons of mortality and incurred expenses. Therefore, we must control these infections by identifying contamination sources. The aim of this study was the determination of bacterial pollution of corrugated anesthesia sets in surgical rooms. Methods: This study was an analytic-description one performed in training hospitals of Yazd ci...

متن کامل

Delivery of heliox with a semi-closed circuit during spontaneous breathing: a comparative economic theoretical study

BACKGROUND Heliox is a mixture of oxygen and helium which reduces airway resistance in patients with airway obstruction. In clinical practice, patients breathing spontaneously receive heliox via an open circuit. Recently, a semi-closed circuit for heliox administration has been proposed which minimizes consumption of heliox and therefore cost of the heliox therapy; although, the semi-closed cir...

متن کامل