Four-dimensional cone-beam computed tomography and digital tomosynthesis reconstructions using respiratory signals extracted from transcutaneously inserted metal markers for liver SBRT.
نویسندگان
چکیده
PURPOSE Respiration-induced intrafraction target motion is a concern in liver cancer radiotherapy, especially in stereotactic body radiotherapy (SBRT), and therefore, verification of its motion is necessary. An effective means to localize the liver cancer is to insert metal fiducial markers to or near the tumor with simultaneous imaging using cone-beam computed tomography (CBCT). Utilizing the fiducial markers, the authors have demonstrated a method to generate breath-induced motion signal of liver for reconstructing 4D digital tomosynthesis (4DDTS) and 4DCBCT images based on phasewise and/or amplitudewise sorting of projection data. METHODS The marker extraction algorithm is based on template matching of a prior known marker image and has been coded to optimally extract marker positions in CBCT projections from the On-Board Imager (Varian Medical Systems, Palo Alto, CA). To validate the algorithm, multiple projection images of moving thorax phantom and five patient cases were examined. Upon extraction of the motion signals from the markers, 4D image sorting and image reconstructions were subsequently performed. In the case of incomplete signals due to projections with missing markers, the authors have implemented signal profiling to replace the missing portion. RESULTS The proposed marker extraction algorithm was shown to be very robust and accurate in the phantom and patient cases examined. The maximum discrepancy of the algorithm predicted marker location versus operator selected location was < 1.2 mm, with the overall average of 0.51 +/- 0.15 mm, for 500 projections. The resulting 4DDTS and 4DCBCT images showed clear reduction in motion-induced blur of the markers and the anatomy for an effective image guidance. The signal profiling method was useful in replacing missing signals. CONCLUSIONS The authors have successfully demonstrated that motion tracking of fiducial markers and the subsequent 4D reconstruction of CBCT and DTS are possible. Due to the significant reduction in motion-induced image blur, it is anticipated that such technology will be useful in image-guided liver SBRT treatments.
منابع مشابه
Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملTumor motion changes in stereotactic body radiotherapy for liver tumors: an evaluation based on four-dimensional cone-beam computed tomography and fiducial markers
BACKGROUND For stereotactic body radiation therapy (SBRT) of liver tumors, tumor motion induced by respiration must be taken into account in planning and treatment. We evaluated whether liver tumor motion at the planning simulation represents liver tumor motion during SBRT, and estimated inter- and intrafractional tumor motion changes in patients undergoing liver SBRT. METHODS Ten patients un...
متن کاملAn algorithm to extract three‐dimensional motion by marker tracking in the kV projections from an on‐board imager: four‐dimensional cone‐beam CT and tumor tracking implications
The purpose of this work is to extract three-dimensional (3D) motion trajectories of internal implanted and external skin-attached markers from kV cone-beam projections and reduce image artifact from patient motion in cone-beam computed tomography (CBCT) from on-board imager. Cone beam radiographic projections were acquired for a mobile phantom and liver patients with internal implanted and ext...
متن کاملLiterature Review Image-guided radiation therapy using computed tomography in radiotherapy
The sharp dose gradients in intensity-modulated radiation therapy increase the treatment sensitivity to various interand intra-fractional uncertainties, in which a slight anatomical change may greatly alter the actual dose delivered. Image-guided radiotherapy refers to the use of advanced imaging techniques to precisely track and correct these patient-specific variations in routine treatment. I...
متن کاملImage quality in extended arc filtered digital tomosynthesis.
PURPOSE To study image quality in filtered digital tomosynthesis (FDTS) tomograms as a function of their reconstruction arc, using isocentrically acquired, fluoroscopic projection data. MATERIAL AND METHODS Both digital tomosynthesis (DTS) and cone beam CT (CBCT) reconstruction algorithms are based on backprojection and use cone beam projection data as input. Under limited angle conditions, C...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical physics
دوره 38 2 شماره
صفحات -
تاریخ انتشار 2011