Live/real time three-dimensional transthoracic echocardiographic assessment of pulmonary regurgitation.

نویسندگان

  • Koteswara R Pothineni
  • Bryan J Wells
  • Ming Chon Hsiung
  • Navin C Nanda
  • Pridhvi Yelamanchili
  • Thouantosaporn Suwanjutah
  • A N Ravi Prasad
  • Sachin Hansalia
  • Chang-Chyi Lin
  • Wei-Hsian Yin
  • Mason-Shing Young
چکیده

There is no gold standard for the measurement of pulmonary regurgitation (PR) severity. Two-dimensional (2D) transthoracic echocardiography is most commonly used to quantify PR severity using color Doppler criteria for aortic regurgitation. However, this method is limited by visualization of only one or two dimensions of the proximal PR jet or vena contracta (VC) precluding accurate assessment of its shape or size. This limitation would be expected to be obviated by three-dimensional (3D) transthoracic echocardiography, which could provide a more accurate quantitative assessment of PR severity. This study evaluated 82 adult patients with PR using 2D and 3D. PR VC area by 3D was obtained by planimetry by positioning the cropping plane exactly parallel to the VC, which was viewed en face by cropping of the 3D data set. Regurgitant volumes were calculated by 2D (assuming a circular VC) and by 3D as a product of the VC and velocity time integral obtained by color Doppler-guided conventional Doppler interrogation of the PR jet.The 3D VC area correlated with 2D jet width (JW)/right ventricular outflow tract (RVOT) width (r = 0.71) and 2D VC area (r = 0.79). 3D JW/RVOT width correlated with 2D JW/RVOT (r = 0.87). 3D regurgitant volumes also correlated with 2D regurgitant volumes (r = 0.76). The 3D VC values of <0.20, 0.20-0.45, 0.46-1.15, and >1.15 cm(2) and regurgitant volumes of <15 ml, 15-50 ml, 51-115 ml, and >115 ml were effective as cutoffs for grades 1, 2, 3, and 4 PR, respectively. In conclusion, quantification of 3D VC area and regurgitant volumes correlate reasonably well with the current 2D methods for measurement of PR. Since 3D visualizes PR VC in three dimensions, it would be expected to provide a more accurate and more quantitative assessment of PR severity as compared to 2D.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of aortic regurgitation by live three-dimensional transthoracic echocardiographic measurements of vena contracta area: usefulness and validation.

In this report, we evaluate 56 consecutive adult patients who underwent standard two-dimensional (2D) and live three-dimensional transthoracic echocardiography (3D TTE), as well as left heart catheterization with aortography (45 patients) or cardiac surgery (11 patients), for evaluation of aortic insufficiency. Similar to the method we previously described for mitral insufficiency, aortic regur...

متن کامل

Role of Transthoracic Echocardiography in the Evaluation of Patients with Retinal Vein Occlusion

   Introduction: Retinal vein occlusion  is a common vascular disorder disrupting vision. Two basic types of RVO are branch retinal vein occlusion and central retinal vein occlusion (CRVO).  Retinal vein occlusion is a multifactor process including systemic illness and local retinal factors.RVO may be associated with atherosclerotic risk factors. We analyzed the role of 2 dimensional transthor...

متن کامل

Transthoracic Echocardiography in Children and Young Adults with Congenital Heart Disease

Transthoracic echocardiography (TTE) is the first-line tool for diagnosis and followup of pediatric and young adult patients with congenital heart disease (CHD). Appropriate use of TTE can reduce the need for more invasive modalities, such as cardiac catheterization and cardiac magnetic resonance imaging. New echocardiographic techniques have emerged more recently: tissue Doppler imaging, tissu...

متن کامل

Echocardiographic findings in athletic horses with pulmonary regurgitation

BACKGROUND: Determining the clinical significance of cardiac murmurs is widely considered in equine practice. Pulmonary murmurs are commonly detected in athletic horses. Echocardiography plays a leading role in assessment of these murmurs. OBJECTIVES: Echocardiographic evaluation of horses with pulmonary regurgitation and determining the importance of pulmonary valve murmurs. METHODS: A total n...

متن کامل

Real-time three-dimensional transthoracic echocardiography.

BACKGROUND Complex anatomy of intra-cardiac structures requires spatial orientation of image in three dimensions for better understanding and enhanced image interpretation. We evaluated the feasibility and efficacy of the emerging 'real-time three-dimensional transthoracic echocardiography' technique for comprehensive assessment of cardiac anatomy, physiology, pathomorphology and pathophysiolog...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Echocardiography

دوره 25 8  شماره 

صفحات  -

تاریخ انتشار 2008