Time Reversal of Ultrasonic Fields - Part 11 : ExperimentalResults

نویسندگان

  • Francois Wu
  • Mathias Fink
چکیده

A time-reversal mirror (TRM) is made of an array of transmit-receive transducers. The incident pressure fieldis sampled, digitized, stored, time-reversed and then re-emitted. This process can be used to focus, through inhomogeneous media, on a reflective target that may behave as an acoustic source after being insonified. A 64-channel prototype has been built and TRM experiments demonstrating the TRM performance are described. Present first is focusing experiments conducted on point targets through different aherrating media. The major result shows that the time-reversal focusing technique compensates for all the distortions whatever the TRM-aberrator distance. When the medium contains several targets, we show that the time-reversal process can be iterated in order to focus on themost reflective one. The last part of the paper deals with lithotripsy applications. Kidney stones are spatially extended targets and TRM experiments have been conducted on several kidney stones located behind inhomogeneous media. They show that the iterative TRM process is able to select one of the kidney stones and to focus on a small portion of it.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time Reversal of Ultrasonic Fields-Part I: Basic Principles

Time reversal of ultrasonic fields represents a way to focus through an inhomogeneous medium. This may be acomplished by a time-reversal mirror ("M) made from an array of transmit-receive transducers that respond linearly and allow the incident acoustic pressure to be sampled. The pressure field is then time-reversed and re-emitted. This process can be used to focus through inhomogeneous media ...

متن کامل

Time-reversal acoustics in biomedical engineering.

Time reversal is a very powerful method for focusing through complex and heterogeneous media and shows very promising results in biomedical applications. In this paper, we review some of the main applications investigated during the past decade. An iterative implementation of the time-reversal process allows tracking gallstones in real time during lithotripsy treatments. In this application dom...

متن کامل

Matching pursuit for decomposition and approximation of ultrasonic pulse-echo wavelet and its application in ultrasonic nondestructive evaluation.

The estimation of the time of arrival (TOA) and/or time of flight of the ultrasonic echoes is essential in ultrasonic nondestructive evaluation. In this paper, matching pursuit method has been used to analyze noisy ultrasonic pulse-echo wavelet and decompose the noisy pulse-echo wavelet into unit-norm vectors. The error ratio of the mean square is used to monitor the acceptability of the unit-n...

متن کامل

Schlieren visualization of ultrasonic standing waves in mm-sized chambers for ultrasonic particle manipulation

BACKGROUND For the design and characterization of ultrasonic particle manipulation devices the pressure field in the fluid cavity is of great interest. The schlieren method provides an optical tool for the visualization of such pressure fields. Due to its purely optical nature this experimental method has got some unique advantages compared to methods like particle tracking. RESULTS A vertica...

متن کامل

Numerical Simulation of Ultrasonic Time Reversal Mirror in a Plate with Defect

The time reversal mirror (TRM) is a method which can be effective in NDE of defects in materials. In this case an input ultrasonic wave is transmitted into the examined sample, then recorded by receiving transducers, time reversed and sent back by the same transducers. A simple numerical model of a solid plate with a crack was developed. The propagation of ultrasonic waves used in time reversal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000