Simultaneous assay of buprenorphine and norbuprenorphine by negative chemical ionization tandem mass spectrometry.

نویسندگان

  • J J Kuhlman
  • J Magluilo
  • E Cone
  • B Levine
چکیده

A method for the simultaneous measurement of buprenorphine and its N-dealkylated metabolite, norbuprenorphine, in human plasma was developed with negative chemical ionization tandem mass spectrometry. Buprenorphine and norbuprenorphine were extracted from biological fluids by solid-phase extraction. The samples were derivatized with heptafluorobutyric anhydride and measured with negative chemical ionization tandem mass spectrometry. Buprenorphine formed a heptafluorobutyryl derivative and norbuprenorphine formed a bis-heptafluorobutyryl derivative; consequently, the sensitivity of norbuprenorphine was substantially higher than buprenorphine. The limit of quantitation (LOQ) for buprenorphine was 0.20 ng/mL, and the LOQ for norbuprenorphine was 0.03 ng/mL. Daily calibration curves were prepared. Buprenorphine was linear from 0.15 ng/mL to 20 ng/mL, and norbuprenorphine was linear between 0.016 ng/mL and 5 ng/mL. Between-run and within-run precision for buprenorphine at 0.5 ng/mL were 13.8% and 9.8%, respectively. Between-run and within-run precision for norbuprenorphine at 0.5 ng/mL were 23.1% and 17.9%, respectively. The molecular anion for buprenorphine was used as a precursor ion, whereas the [M-197]- was used as a precursor ion for norbuprenorphine in tandem mass spectrometry. Product ion spectra from collision-induced dissociation resulted principally from dissociations of the heptafluorobutyryl group. Monitoring select precursor to product ion reactions and using qualifier ion ratios increased the method's sensitivity and selectivity. The method was applied to samples collected from a patient who received oral and subcutaneous buprenorphine. Buprenorphine plasma concentrations ranged from less than 0.20 ng/mL to 8.7 ng/mL.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A sensitive, simple and rapid HPLC–MS/MS method for simultaneous quantification of buprenorpine and its N-dealkylated metabolite norbuprenorphine in human plasma

A sensitive, simple and rapid high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed and fully validated for the simultaneous quantification of buprenorphine (BUP) and its N-dealkylated metabolite norbuprenorphine (NBUP) in 200 μL human plasma. Human plasma samples were prepared using liquid-liquid extraction, and then separated on a Shiseido MG C18 (5...

متن کامل

Novel metabolites of buprenorphine detected in human liver microsomes and human urine.

The in vitro metabolism of buprenorphine was investigated to explore new metabolic pathways and identify the cytochromes P450 (P450s) responsible for the formation of these metabolites. The resulting metabolites were identified by liquid chromatography-electrospray ionization-tandem mass spectrometry. In addition to norbuprenorphine, two hydroxylated buprenorphine (M1 and M2) and three hydroxyl...

متن کامل

Simultaneous determination of buprenorphine and norbuprenorphine in serum by high-performance liquid chromatography-electrospray ionization-mass spectrometry.

Buprenorphine is a strong narcotic analgesic. It is also used in the substitution therapy for opium alkaloid addicts. The aim of this paper was to develop and validate a highly sensitive high-performance liquid chromatography-electrospray ionization-mass spectrometry method for simultaneous determination of buprenorphine and norbuprenorphine in human serum. The developed methodology was then ap...

متن کامل

Buprenorphine detection in urine using liquid chromatography-high-resolution mass spectrometry: comparison with cloned enzyme donor immunoassay (ThermoFisher) and homogeneous enzyme immunoassay (immunalysis).

A sensitive liquid chromatographic-high-resolution mass spectrometric (LC-HR-MS) assay for buprenorphine and its urinary metabolites has been developed that requires minimal sample preparation. The results obtained have been compared with those given by (i) cloned enzyme donor immunoassay (CEDIA) and (ii) homogeneous enzyme immunoassay (HEIA) in the analysis of patient urines submitted for bupr...

متن کامل

Quantification of Buprenorphine, Norbuprenorphine and 6-Monoacetylmorphine in Urine by Liquid Chromatography-Tandem Mass Spectrometry

Monitoring pain management medications and illicit drugs in urine is commonly used to assess patient compliance. Previously, we developed a liquid chromatography tandem mass spectrometry (LC-MS/MS) method to measure 19 analytes important for pain management. In the current report, we validated this method for two additional drugs, buprenorphine and heroin. For buprenorphine, we quantified both ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of analytical toxicology

دوره 20 4  شماره 

صفحات  -

تاریخ انتشار 1996