Are porous tantalum cups superior to conventional reinforcement rings?

نویسندگان

  • Anders Brüggemann
  • Erik Fredlund
  • Hans Mallmin
  • Nils P Hailer
چکیده

Background and purpose - Porous tantalum cups have been introduced as an alternative to various reinforcement rings in revision hip surgery. We hypothesized that porous tantalum cups would be superior to Müller acetabular roof reinforcement rings (MARRs) in revision hip surgery with re-revision for aseptic loosening as the primary outcome measure. Patients and methods - 207 hips operated with either a porous tantalum cup (TM cup, n = 111) or a MARR (n = 96) at index procedure were identified in our local arthroplasty register. Acetabular defects were classified according to Paprosky. There were 96 men and 111 women with a median age of 71 (35-95) years, presenting acetabular defect size type I in 39 cases, IIA in 22, IIB in 27, IIC in 43, IIIA in 32, and IIIB in 37 cases. Analysis of medical records identified all patients with subsequent re-revision and reasons for re-revisions. Kaplan-Meier survival functions were used to estimate implant survival. Results - With re-revision for aseptic loosening as the endpoint, the 6-year unadjusted cumulative survival was 97% (95% CI: 94-100) for TM cups and 96% (CI: 92-100) for MARR (p = 0.6). Using re-revision for any reason as the endpoint, 6-year survival was 87% (CI: 81-94) for TM cups and 95% (CI: 90-99) for MARR (p = 0.06). The main reason for re-revision in the TM group was dislocation (n = 10), followed by loosening (n = 3), whereas the main reason for re-revision in the MARR group was aseptic loosening (n = 8). Duration of the index procedure and perioperative blood loss were lower in the TM group. Interpretation - Both TM and MARR lead to good 6-year results in acetabular revision surgery. The methods differ in their respective failure mechanisms. We conclude that TM cups are a valuable treatment option in acetabular revision surgery, but the reasons underlying dislocations after the use of TM cups must be analyzed further.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A retrospective cohort study of 207 acetabular revisions

© 2016 The Author(s). Published by Taylor & Francis on behalf of the Nordic Orthopedic Federation. This is an Open Access article distributed under the terms of the Creative Commons Attribution-Non-Commercial License (https://creativecommons.org/licenses/by-nc/3.0) DOI 10.1080/17453674.2016.1248315 Background and purpose — Porous tantalum cups have been introduced as an alternative to various r...

متن کامل

Options for managing severe acetabular bone loss in revision hip arthroplasty. A systematic review.

Revision hip arthroplasty in the presence of severe acetabular bone loss is challenging and requires a solid understanding of current techniques. A literature search of multiple databases applying specific criteria revealed a total of 50 articles of level IV scientific evidence comprising 2415 patients (2480 hips) managed with reinforcement devices (roof-reinforcement rings and anti-protrusio c...

متن کامل

Finite Element Analysis Stress Distribution Acetabular Cup Biomaterial FINITE ELEMENT ANALYSIS OF PERI-ACETABULAR STRESS OF CEMENTED, METAL-BACKED, AND POROUS TANTALUM BACKED ACETABULAR COMPONENTS

Introduction: In contemporary THA there are two broad approaches to acetabular cup design and materials. One is an all-polyethylene design with polymethylmethacrylate (PMMA) cement. PMMA possesses a modulus of elasticity of about 2 GPa, which is between that of trabecular and subchondral bone. The second more popular approach, especially for active, younger patients, is the porous metal-backed ...

متن کامل

A Novel Method for Assessment of Polyethylene Liner Wear in Radiopaque Tantalum Acetabular Cups: Clinical Validation in Patients Enrolled in a Randomized Controlled Trial.

Conventional radiostereometric analysis (RSA) for wear is not possible in patients with tantalum cups. We propose a novel method for wear analysis in tantalum cups. Wear was assessed by gold standard RSA and the novel method in total hip arthroplasty patients enrolled in a randomized controlled trial receiving either titanium or tantalum cups (n=46). The novel method estimated the center of the...

متن کامل

Hedrocel trabecular metal monoblock acetabular cups: mid-term results.

The most important factors for long-term survival of cementless prostheses are the initial fixation, the osteoconducting properties of the metal shell and the bony response. Porous tantalum, a new biomaterial with a geometric structure similar to trabecular bone, was reported in animal studies to allow for bone ingrowth even when 3-mm gaps exist between the implant and the bone. This new materi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 88  شماره 

صفحات  -

تاریخ انتشار 2017