MRI Reduces Variation of Contouring for Boost Clinical Target Volume in Breast Cancer Patients Without Surgical Clips in the Tumour Bed
نویسندگان
چکیده
BACKGROUND Omitting the placement of clips inside tumour bed during breast cancer surgery poses a challenge for delineation of lumpectomy cavity clinical target volume (CTVLC). We aimed to quantify inter-observer variation and accuracy for CT- and MRI-based segmentation of CTVLC in patients without clips. PATIENTS AND METHODS CT- and MRI-simulator images of 12 breast cancer patients, treated by breast conserving surgery and radiotherapy, were included in this study. Five radiation oncologists recorded the cavity visualization score (CVS) and delineated CTVLC on both modalities. Expert-consensus (EC) contours were delineated by a senior radiation oncologist, respecting opinions of all observers. Inter-observer volumetric variation and generalized conformity index (CIgen) were calculated. Deviations from EC contour were quantified by the accuracy index (AI) and inter-delineation distances (IDD). RESULTS Mean CVS was 3.88 +/- 0.99 and 3.05 +/- 1.07 for MRI and CT, respectively (p = 0.001). Mean volumes of CTVLC were similar: 154 +/- 26 cm3 on CT and 152 +/- 19 cm3 on MRI. Mean CIgen and AI were superior for MRI when compared with CT (CIgen: 0.74 +/- 0.07 vs. 0.67 +/- 0.12, p = 0.007; AI: 0.81 +/- 0.04 vs. 0.76 +/- 0.07; p = 0.004). CIgen and AI increased with increasing CVS. Mean IDD was 3 mm +/- 1.5 mm and 3.6 mm +/- 2.3 mm for MRI and CT, respectively (p = 0.017). CONCLUSIONS When compared with CT, MRI improved visualization of post-lumpectomy changes, reduced interobserver variation and improved the accuracy of CTVLC contouring in patients without clips in the tumour bed. Further studies with bigger sample sizes are needed to confirm our findings.
منابع مشابه
Can radiographic plain film be used to determine the depth of the tumour bed in the absence of surgical clips for breast boost planning
PURPOSE A number of studies have demonstrated the importance of using surgical clips to define the tumour bed in breast boost radiotherapy. In the absence of such clips, other techniques suggested to improve boost location have included CT and ultrasound (US). Determination of the depth of the tumour bed is important in the selection of electron energy. This study was conducted to prospectively...
متن کاملBreast Boost: Are We Missing the Target? A Dosimetric Comparison of Two Boost Techniques
Received July 19, 2002; revision received September 16, 2002; accepted September 24, 2002. BACKGROUND. Randomized trials have shown improved local control with the use of a breast boost for patients given breast-conserving treatment for breast carcinoma. Although the use of a breast boost is routine practice, no standard technique has been established. The authors compared the commonly used cli...
متن کاملPartial Breast and Breast Boost Radiotherapy Planned in the Prone Position: What Does MRI Add to X-ray CT Localization of Titanium Clips Placed in the Excision Cavity Wall?, International Journal of Radiation Oncology Biology Physics
Purpose: To compare tumour bed (TB) volumes delineated using MRI plus CT/clips (MRCT) with those delineated using CT/clips-alone in post-lumpectomy breast cancer patients positioned prone, and to determine the value of MRCT for planning partial breast radiotherapy (PBI). Materials/ Methods: 30 women with breast cancer each had 6-12 titanium-clips secured in the excision cavity walls at lumpecto...
متن کاملDosimetric Evaluation of Target Volume in Breast Boost Radiotherapy: Comparison of Electron and Photon Beam
Background and purpose: Breast‑conserving surgery followed by radiation therapy to the whole breast is now recognized as a standard strategy in patients with breast cancer. Recommended technique for radiotherapy is whole breast irradiation followed by boost to the tumor bed. This study aimed to compare the dosimetric parameters of electron and photon beams for boosting irradiation in post‑lump...
متن کاملA topology-based method to mitigate the dosimetric uncertainty caused by the positional variation of the boost volume in breast conservative radiotherapy
BACKGROUND To improve local control rate in patients with breast cancer receiving adjuvant radiotherapy after breast conservative surgery, additional boost dose to the tumor bed could be delivered simultaneously via the simultaneous integrated boost (SIB) modulated technique. However, the position of tumor bed kept changing during the treatment course as the treatment position was aligned to bo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 51 شماره
صفحات -
تاریخ انتشار 2017