[Short-tau inversion-recovery (STIR) sequence magnetic resonance imaging evaluation of orbital structures in Graves' orbitopathy].
نویسندگان
چکیده
OBJECTIVE To evaluate the orbital structures and to establish correlations with disease activity and severity in patients with Graves' hyperthyroidism and orbitopathy (GO) using short-tau inversion-recovery (STIR) sequence magnetic resonance imaging (MRI). METHODS Observational, cross-sectional, case-control study. Twenty-eight patients with euthyroid status after treatment and GO (GO group) and 15 control subjects (control group) were included. Patients underwent a complete ophthalmologic examination and were then assessed according to the EUGOGO (European Group on Graves' Orbitopathy) recommendations. Muscle cross-sectional areas, orbital tissue volumes and the signal intensity ratio (SIR) from the most inflamed extraocular muscle were calculated using a STIR-T2 weighted sequence MRI. Correlations between clinical and MRI measurements were analyzed. RESULTS Enlargements in the cross-sectional areas and volumes were significant for most EOMs (P<.001), but not for the lateral rectus muscle cross-sectional area. A significant difference in SIR values between patients with GO and control subjects (P<.001) was found. No significant correlations were found between muscle cross-sectional areas, orbital tissue volumes, SIR values and the clinical activity parameters. CONCLUSIONS Given the small sample size of our study, with the obvious need for larger clinical trials, we were unable to demonstrate that the STIR sequences in MRI are a sensitive tool in assessing patients with longstanding GO in order to detect inflammatory changes and activity follow-up, possibly because it is in inactive phase. Meanwhile, it is still necessary to continue performing a thorough clinical evaluation in the therapeutic management of GO.
منابع مشابه
Clinical and imaging evaluation of the response to intravenous steroids in patients with Graves’ orbitopathy and analysis on who requires additional therapy
OBJECTIVE The aim of this study was to evaluate the safety and efficacy of an individualized steroid regimen in patients with moderate-to-severe Graves' orbitopathy (GO) by monitoring clinical and imaging parameters. METHODS In total, 47 patients with active, moderate-to-severe GO were enrolled in this study. All the patients received the proposed treatment regimen by European Group on GO of ...
متن کاملOptimization of inversion time for postmortem short-tau inversion recovery (STIR) MR imaging.
PURPOSE Signal intensity and image contrast differ between postmortem magnetic resonance (PMMR) images and images acquired from the living body. We sought to achieve sufficient fat suppression with short-tau inversion recovery (STIR) PMMR imaging by optimizing inversion time (TI). MATERIAL AND METHODS We subjected 37 deceased adult patients to PMMR imaging at 1.5 tesla 8 to 60 hours after con...
متن کاملImaging myocardial carcinoid with T2-STIR CMR
We used T2-STIR (Short Tau Inversion Recovery) cardiovascular magnetic resonance to demonstrate carcinoid tumor metastases to the heart and liver in a 64-year-old woman with a biopsy-proven ileal carcinoid tumor who was referred because of an abnormal echocardiogram.
متن کاملComparison of Cartesian and radial acquisition on short-tau inversion recovery (STIR) sequences in breast MRI
OBJECTIVE The purpose of this study was to compare two short-tau inversion recovery (STIR) sequences, Cartesian and radial (BLADE) acquisitions, for breast magnetic resonance imaging (MRI) examinations. MATERIALS AND METHODS Ninety-six women underwent 1.5 T breast MRI exam (48 Cartesian and 48 BLADE). Qualitative analysis including image artifacts, image quality, fat-suppression, chest-wall d...
متن کاملThe STIR sequence in MR imaging.
A recent paper on MR imaging of infectious spondylitis [1) elaborated on and substantiated a previous report [2) of STIR in the evaluation of spinal infection. However, it also contained an important error in pulse sequence nomenclature: STIR was described as "short T1 inversion recovery. " The STIR sequence was described and named by Drs. Bydder, Young, and Steiner [3 , 4) as "short Tl inversi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Archivos de la Sociedad Espanola de Oftalmologia
دوره 86 11 شماره
صفحات -
تاریخ انتشار 2011