Characteristics, Dosimetry & Measurement of Emf
نویسندگان
چکیده
This paper describes characteristics of electromagnetic fields and their interaction with body as a fundamentals of electromagnetic field (EMF) safety issue. It also presents how engineering and physics contribute to this. EMF should be appropriately and precisely characterized when we consider its interaction with body. Dosimetry, which is the quantification of substance interacting with the exposed body, is of quite importance in the exposure assessment for both compliance testing with guidelines and the quality control of researches on EMF effects. The basic concept of these issues is summarized, and some researches mainly performed by the authors’ group are presented as exa mples of researches in this field.
منابع مشابه
A Source-based Measurement Database for Occupational Exposure Assessment of Electromagnetic Fields in the INTEROCC Study: A Literature Review Approach
INTRODUCTION To date, occupational exposure assessment of electromagnetic fields (EMF) has relied on occupation-based measurements and exposure estimates. However, misclassification due to between-worker variability remains an unsolved challenge. A source-based approach, supported by detailed subject data on determinants of exposure, may allow for a more individualized exposure assessment. Deta...
متن کاملNon-ionizing electromagnetic waves measurement and monitoring Systems
In this paper, portable and online monitoring systems for non-ionizing EMF measurement, as well as some measurement results in Tehran are discussed. First of all, standards and recommendations related to EMF monitoring, measurement and exposure such as ISIRI No.8567, ICNIRP guideline and ITU-K.83 are reviewed. Then, technical facts and operation of portable device and monitoring station are int...
متن کاملAdaptive framework for uncertainty analysis in electromagnetic field measurements.
Misinterpretation of uncertainty in the measurement of the electromagnetic field (EMF) strength may lead to an underestimation of exposure risk or an overestimation of required measurements. The Guide to the Expression of Uncertainty in Measurement (GUM) has internationally been adopted as a de facto standard for uncertainty assessment. However, analyses under such an approach commonly assume u...
متن کاملThe physical characteristics of a SLIC-EPID for transmitted dosimetry
ABSTRACT Background: for treatment verification in radiation therapy. Several physical characteristics of ScanningLiquid filled Ionization Chamber EPID (SLIC-EPID) including: extra build-up layer,reproducibility and uniformity, and noise level were investigated.Electronic Portal Imaging Devices (EPIDs) have found an outstanding positionMaterials and Methods: equilibrium, 1-30 mm white water mat...
متن کاملDose distribution and dosimetry parameters calculation of MED3633 palladium-103 source in water phantom using MCNP
Background: Palladium-103 (103Pd) is a brachytherapy source for cancer treatment. The Monte Carlo codes are usually applied for dose distribution and effect of shieldings. Monte Carlo calculation of dose distribution in water phantom due to a MED3633 103Pd source is presented in this work. Materials and Methods: The dose distribution around the 103Pd Model MED3633 located in the center of 30×...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -