Evaluation of auto-regulated inspiratory support during rebreathing and acute lung injury in pigs.
نویسندگان
چکیده
BACKGROUND Auto-regulated inspiratory support mode (ARIS) is an original closed-loop pressure-support system that regulates the slope ("A") and the initial level ("B") of the applied inspiratory pressure, in order to achieve an optimal minute ventilation under constrained respiratory frequency, tidal volume, and maximum inspiratory airway pressure. The servo-controlled design results in a more or less decreasing applied pressure. OBJECTIVE The aim of this study was to evaluate the ARIS behavior, compared with pressure-support ventilation at a constant applied pressure. METHODS ARIS and pressure-support ventilation were randomly applied to 2 pig models of increasing ventilatory demand induced by a rebreathing test (n = 6), and of altered lung compliance induced by bronchoalveolar lavage (n = 6). The breathing pattern, work of breathing, and blood gas values were compared. ARIS automatically increased the mean inspiratory airway pressure in both groups. This increase was obtained in the rebreathing group by increasing "B" (35 +/- 3.5 cm H2O vs 42.8 +/- 2.5 cm H2O) and in the lung-injury group by decreasing the absolute value of "A" (25 +/- 5.5 cm H2O/s vs 14.7 +/- 8.6 cm H2O/s). RESULTS There were significant differences (p < 0.05) between ARIS and pressure-support ventilation. In the rebreathing group, tidal volume was 692 +/- 63 mL versus 606 +/- 96 mL, work of breathing was 1.17 +/- 0.45 J/L versus 1.44 +/- 0.27 J/L, and P(aCO2) was 54 +/- 9 mm Hg versus 63 +/- 7 mm Hg. In the lung-injury group, respiratory frequency was 25 +/- 4 breaths/min versus 42 +/- 10 breaths/min, tidal volume was 477 +/- 67 mL versus 300 +/- 63 mL, work of breathing was 0.54 +/- 0.3 J/L versus 0.99 +/- 0.45 J/L, and P(aCO2) was 36 +/- 8 mm Hg versus 53 +/- 15 mm Hg. CONCLUSIONS The ARIS servo control operates correctly, maintaining efficient ventilation facing an increase in respiratory demand or a decrease in respiratory system compliance.
منابع مشابه
Effect of manufacturer-inserted mask leaks on ventilator performance.
Most pressure-support devices use a single circuit with an exhalation port integrated in the mask. The aim of the current study was to compare the effects of masks having different manufacturer-inserted leaks on ventilator performance. We simulated chronic obstructive pulmonary disease and restrictive disease. Four ventilators (VENTImotion (Weinmann, Hamburg, Germany), VPAP III STA (ResMed, Sai...
متن کاملEffects of peak inspiratory flow on development of ventilator-induced lung injury in rabbits.
BACKGROUND A lung-protecting strategy is essential when ventilating acute lung injury/acute respiratory distress syndrome patients. Current emphasis is on limiting inspiratory pressure and volume. This study was designed to investigate the effect of peak inspiratory flow on lung injury. METHODS Twenty-four rabbits were anesthetized, tracheostomized, ventilated with a Siemens Servo 300, and ra...
متن کاملTime-dependent changes of autophagy and apoptosis in lipopolysaccharide-induced rat acute lung injury
Objective(s): Abnormal lung cell death including autophagy and apoptosis is the central feature in acute lung injury (ALI). To identify the cellular mechanisms and the chronology by which different types of lung cell death are activated during lipopolysaccharide (LPS)-induced ALI, we decided to evaluate autophagy (by LC3-II and autophagosome) and apoptosis (by caspase-3) at different time point...
متن کاملTime course changes of oxidative stress and inflammation in hyperoxia-induced acute lung injury in rats
Objective(s):Therapies with high levels of oxygen are commonly used in the management of critical care. However, prolonged exposure to hyperoxia can cause acute lung injury. Although oxidative stress and inflammation are purported to play an important role in the pathogenesis of acute lung injury, the exact mechanisms are still less known in the hyperoxic acute lung injury (HALI). Materials ...
متن کاملEvaluation of a CO2 Partial Rebreathing-Based Functional Residual Capacity Measurement Method for Mechanically Ventilated Patients
There is a need for an automated bedside functional residual capacity (FRC) measurement method that can continually monitor both the size and a change in size of a patient’s lung volume during mechanical ventilation without the use of bulky equipment, expensive tracer gases or step increases in inspired oxygen fraction. We developed a CO2 rebreathing method for FRC measurement that simply requi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Respiratory care
دوره 50 8 شماره
صفحات -
تاریخ انتشار 2005