On the use of positioning aids to reduce misregistration in the head and neck in whole-body PET/CT studies.
نویسندگان
چکیده
UNLABELLED Involuntary patient motion from insufficient patient preparation may lead to local misregistration of PET/CT images and, thus, can invalidate the attempt to fuse the resulting images. We estimate the efficacy of selected patient support structures in reducing the likelihood of patient motion in the area of the head and neck during whole-body PET/CT studies. METHODS Motion of the head and neck was estimated in 51 healthy volunteers during simulated whole-body PET/CT studies using an infrared camera-based tracking system. Four patient positioning schemes (arms down) were studied, with the neck placed on a standard PET head holder with no support at the sides (setup A), on a special head holder fitted with a subject-specific mold from construction foam (setup B), on a vacuum-lock bag (setup C), and on a special head holder fitted with a vacuum-lock bag (setup D). We report the average motion of the head and neck as the difference in the position of a set of target points between the simulated CT image and PET image of the head and neck. To estimate the efficacy of additional patient support measures in clinical practice, we reviewed the misregistration of the head and neck in whole-body PET/CT studies of 10 patients each who were imaged using setups A and C by comparing the mean translational and rotational alignment parameters from a semiautomatic linear registration approach needed to realign the CT and PET images. RESULTS Average translational and rotational misalignment of the head and neck was highest for setup A, at 7 mm and 1 degrees , respectively. Misalignment was reduced to a minimum of 1.4 mm and 0.3 degrees for setup D. Setup B resulted in a similar reduction in patient motion of the head and neck: 2.4 mm and 0.4 degrees , whereas setup C provided only somewhat improved support, with a resulting average misalignment of 4.5 mm and 0.7 degrees. In clinical PET/CT, we found setup C to reduce translational misalignment of the CT and PET images of the head and neck to 2 mm, compared with 6 mm for setup A, whereas no significant reduction of rotational misalignment was observed. CONCLUSION Average motion of the head and neck in unrestrained subjects during whole-body PET/CT examinations can be reduced by use of rigid positioning aids, such as foam molds, or vacuum-lock bags. Vacuum-lock bags are reusable, quickly adaptable, and olfactory neutral and can be used routinely, either alone or in combination with a head holder, in whole-body PET/CT for high-quality examinations.
منابع مشابه
Value of Dedicated Head and Neck 18F-FDG PET/CT Protocol in Detecting Recurrent and Metastatic Lesions in Post-surgical Differentiated Thyroid Carcinoma Patients with High Serum Thyroglobulin Level and Negative 131I Whole-body Scan
Objective(s): In clinical practice, approximately 10-25% of post-surgical differentiated thyroid carcinoma (DTC) patients with high serum thyroglobulin (Tg) and negative 131I whole-body scan (WBS) have poor prognosis due to recurrent or metastatic lesions after radioactive iodine treatment. The purpose of this study was to evaluate the value of 18F-FDG PET/CT scan in DTC patients with high seru...
متن کاملRare ocular and skin lesions of Marginal Zone Lymphoma detected by 18F-FDG PET/CT
We report a case of a 75-year old man that came at hematologist’s attention for lymphoma evaluation due to axillary lymph node enlargement and fever. Thorax, abdomen and pelvis Contrast-Enhanced Computed Tomography (CECT) showed lymph nodes, spleen and liver lesions. Axillary lymph node biopsy was performed and the diagnosis of marginal zone lymphoma (MZL) at stage IV was postulated, then the p...
متن کاملThyroid dose and dose reduction method from CT scan of head and neck
Introduction: Computed tomography (CT) consists of 11% of all imaging methods, but accounts for approximately 67% of radiation exposure due to diagnostic cases. More than one-third of all CT scans are done in the head and neck area. The thyroid gland is irradiated during CT head and neck. According to studies, this gland has the highest levels of radiation-induced cancer, and i...
متن کاملUncertainties in effective dose estimation for CT transmission scan in total body PET-CT imaging with Auto mA3D tube current modulation
Background: Positron Emission Tomography-Computed Tomography (PET-CT) is a useful hybrid imaging modality in the diagnosis of various malignancies. This modality imposes almost 20 mSv radiation dose to the patient. The purpose of the present study was to evaluate the uncertainties in calculated CT effective dose in TUBE CURRENT MODULATION-activated scans by Impact-Dose software. Materials and ...
متن کاملEvaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry
Background: PET/CT imaging using [18F]-FDG is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. Essential consideration must be taken for radiation staff due to high gamma radiation in PET/CT and cyclotron center. The aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in PET/CT an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 46 4 شماره
صفحات -
تاریخ انتشار 2005