Assessment of coronary artery bypass graft disease using cardiovascular magnetic resonance determination of flow reserve.
نویسندگان
چکیده
OBJECTIVES The purpose of this study was to assess the value of cardiovascular magnetic resonance (CMR)-determined graft flow and flow reserve in differentiating significant from non-significant vein graft disease. BACKGROUND In patients after coronary artery bypass grafting (CABG), non-invasive testing may be helpful in the detection of recurrent graft disease. METHODS Randomly selected patients (n = 21) scheduled for X-ray angiography because of recurrent chest complaints after CABG were included for evaluation of vein grafts (n = 40) by CMR. Three-dimensional contrast-enhanced CMR angiography was performed and followed by flow measurements at rest and during hyperemia in patent grafts only. Flow reserve was calculated when resting flow exceeded 20 ml/min. Analysis was based on four categories defined by X-ray angiography: occluded grafts (n = 3), grafts with stenosis >50% (n = 19), grafts with stenosis <50% with diseased graft run-off (n = 8), and grafts with stenosis <50% and normal run-off (n = 10). RESULTS The CMR angiography demonstrated occlusion of three grafts. In nine of the 37 patent grafts, basal blood flow was <20 ml/min, all demonstrating significant stenosis at X-ray angiography. In grafts with resting flow >20 ml/min (n = 28), flow reserve significantly differed between grafts without stenosis and grafts with significant stenosis or with diseased run-off (2.5 +/- 0.7 vs. 1.8 +/- 0.9, p = 0.04). An algorithm combining basal volume flow <20 ml/min and graft flow reserve <2 had a sensitivity and specificity of 78% and 80% respectively for detecting grafts with significant stenosis or diseased run-off. CONCLUSIONS This feasibility study showed that quantification of flow and flow reserve by CMR may serve as a non-invasive adjunct to differentiate between vein grafts without stenosis and grafts with significant stenosis or diseased run-off.
منابع مشابه
Validation of a high-resolution, phase contrast cardiovascular magnetic resonance sequence for evaluation of flow in coronary artery bypass grafts.
The aim was to validate a magnetic resonance high-resolution, phase-contrast sequence for quantifying flow in small and large vessels and to demonstrate its feasibility to measure flow in coronary artery bypass grafts. A breathhold, echo planar imaging (EPI) sequence was developed and validated in a flow phantom using a fast field echo (FFE) sequence as reference. In 17 volunteers aortic flow w...
متن کاملEvaluation of saphenous vein coronary artery bypass graft flow by cardiovascular magnetic resonance.
Cardiovascular magnetic resonance (CMR) with flow velocity mapping has emerged as a noninvasive method to measure flow in saphenous vein coronary artery bypass grafts. The aim of the current study was to retrospectively test two previously described analysis methods on a large CMR data set and to compare their diagnostic accuracy in detecting diseased vein grafts. In 125 vein grafts of 68 patie...
متن کاملCoronary Artery Disease Risk Factors in Patients Undergoing Coronary Artery Bypass Graft Surgery
Introduction: Nowadays, with the advancement of technology and industrial life, the prevalence of heart diseases including coronary artery diseases has considerably increased. Coronary artery diseases are one of the most common and serious diseases that threaten human life. Methods: The present study is a comparative-descriptive research. The statistical ...
متن کاملComparison of Treatment Outcomes in Off-pump Coronary Artery Bypass Graft and Medical Therapy in Patients with Triple-vessel Coronary Artery Disease and Severe Ventricular Dysfunction
Introduction: Heart failure is a major hazard for public health. Despite recent advance in medical therapy, there is not enough information on the outcome of off-pump coronary artery bypass (OPCAB) and medical therapy on the patients with severe ventricular dysfunction and triple-vessel (CAD). This study aimed to compare treatment outcomes and mortality rate in patients undergoing off-pump coro...
متن کاملPredictors' issues of intubation time after coronary artery bypass graft surgery
Abstract Introduction: Cardiovascular illness is the common disease in developed countries. Among of these illnesses the coronary artery failure significantly counted as a high rate of heart disease in the world. The main treatment for this condition is replacing coronary artery bypass graft (CABG) heart pump under surgical crew including skilled nurses. Objective: This study aimed to det...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the American College of Cardiology
دوره 40 10 شماره
صفحات -