Assessment of Special Care Newborn Units in India
نویسندگان
چکیده
The neonatal mortality rate in India is high and stagnant. Special Care Newborn Units (SCNUs) have been set up to provide quality level II newborn-care services in several district hospitals to meet this challenge. The units are located in some remotest districts where the burden of neonatal deaths is high, and access to special newborn care is poor. The study was conducted to assess the functioning of SCNUs in eight rural districts of India. The evaluation was based on an analysis of secondary data from the eight units that had been functioning for at least one year. A cross-sectional survey was also conducted to assess the availability of human resources, equipment, and quality care. Descriptive statistics were used for analyzing the inputs (resources) and outcomes (morbidity and mortality). The rate of mortality among admitted neonates was taken as the key outcome variable to assess the performance of the units. Chi-square test was used for analyzing the trend of case-fatality rate over a period of 3-5 years considering the first year of operationalization as the base. Correlation coefficients were estimated to understand the possible association of case-fatality rate with factors, such as bed:doctor ratio, bed:nurse ratio, average duration of stay, and bed occupancy rate, and the asepsis score was determined. The rates of admission increased from a median of 16.7 per 100 deliveries in 2008 to 19.5 per 100 deliveries in 2009. The case-fatality rate reduced from 4% to 40% within one year of their functioning. Proportional mortality due to sepsis and low birthweight (LBW) declined significantly over two years (LBW <2.5 kg). The major reasons for admission and the major causes of deaths were birth asphyxia, sepsis, and LBW/prematurity. The units had a varying nurse:bed ratio (1:0.5-1:1.3). The bed occupancy rate ranged from 28% to 155% (median 103%), and the average duration of stay ranged from two days to 15 days (median 4.75 days). Repair and maintenance of equipment were a major concern. It is possible to set up and manage quality SCNUs and improve the survival of newborns with LBW and sepsis in developing countries, although several challenges relating to human resources, maintenance of equipment, and maintenance of asepsis remain.
منابع مشابه
Challenges in scaling up of special care newborn units--lessons from India.
Neonatal mortality rate in India is high and stagnant. Special Care Newborn Units (SCNUs) are being set up to provide quality level II newborn care services in district hospitals of several districts to meet this challenge. The units are located in some of the remotest districts where the burden of neonatal deaths and accessibility to special care is a concern. A recently concluded evaluation...
متن کاملRadiation cancer risk from doses to newborn infants hospitalized in neonatal intensive care units in children hospitals of Isfahan province
Background: This study aimed to investigate dose area product (DAP), effective dose, and radiation risk in newborn infants hospitalized in neonatal intensive care units in Isfahan and Kashan. Materials and Methods: During a period of six months, DAP for chest X-ray examinations for newborn infants hospitalized in NICUs of five special hospitals including Beheshti (in Kashan), Al-Zahra, Imam Hos...
متن کاملNewborn Aides: An Innovative Approach in Sick Newborn Care at a District-level Special Care Unit
A Sick Newborn Care Unit (SNCU), established in a district hospital in India, substantially reduced the neonatal mortality rate in the district; it, however, suffered from a dearth of trained nurses. Local girls with 10-12 years of school education underwent structured and hands-on training for six months, followed by a six-month internship at the SNCU and were assigned to it as stipendiary 'Ne...
متن کاملCOMPARISON OF EVALUATION OF PATIENT SAFETY ASSESSMENT INDICATORS IN SPECIAL SECTIONS HOSPITALS PRIVATE AND EDUCATIONAL AHVAZ UNIVERSITY OF MEDICAL SCIENCES IN 2019
Background & Aims: One of the most important issues in the health care system is the observance of patient safety indicators, especially in special sections. In this regard, the evaluation of patient safety assessment in Special care wards as an issue It is always important. Objective: The aim of this study was to evaluate the evaluation of patient safety assessment indicators in the special wa...
متن کاملInvestigating the Information Technology Competency of Nurses in Critical Care Units: A cross-sectional study
Introduction: With the rapid growth of information technology (IT) and the expectations of health care environments, the presence of nurses with informatics skills in the health care environment to effectively use and manage health care information in health care delivery seems necessary; therefore, this study was conducted to evaluate the IT competency of special care nurses from their point o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 29 شماره
صفحات -
تاریخ انتشار 2011