Impact of Competitive Flow on Hemodynamics in Coronary Surgery: Numerical Study of ITA-LAD Model
نویسندگان
چکیده
Competitive flow from native coronary artery is considered as a major factor in the failure of the coronary artery bypass grafts. However, the physiological effects are not very clear. The aim is to research the impact of competitive flow caused by different left anterior descending (LAD) artery stenosis degrees on hemodynamics in internal thoracic artery (ITA) bypass graft. An idealized ITA-LAD model was built in CAD tools. The degree of the competitive flow was divided into five classes according to different LAD stenosis degrees: higher (no stenosis), secondary (30% stenosis), reduced (50% stenosis), lower (75% stenosis) and no competitive flow (fully stenosis). Finite volume method was employed for the numerical simulation. The flow velocity distributions, wall shear stress and oscillatory shear index were analyzed. Results showed that higher competitive flow in the bypass graft would produce unbeneficial wall shear stress distribution associating with endothelial dysfunction and subsequent graft failure. The coronary bypass graft surgery was preferred to be carried out when the LAD stenosis was higher than 75%.
منابع مشابه
Patency rate of the internal thoracic artery to the left anterior descending artery bypass is reduced by competitive flow from the concomitant saphenous vein graft in the left coronary artery.
OBJECTIVE In coronary artery bypass grafting (CABG), insufficient bypass flow can be a cause of occlusion or string sign of the internal thoracic artery (ITA) graft. A patent saphenous vein (SV) graft from the ascending aorta can reduce the blood flow through the ITA graft, and may affect its long-term patency. In the present study, we examined the impact of the patent SV graft to the left coro...
متن کاملAngiographic evaluation of flow distribution in sequential and composite arterial grafts for three vessel disease.
OBJECTIVES We sought to delineate the effects of the severity of target lesions and their combinations on the occurrence of competitive flow, especially in the composite Y-graft and to establish an optimal strategy for graft arrangement and patient selection. METHODS We reviewed early and late angiograms of 2514 bypass grafts in 601 patients, who underwent off-pump coronary revascularization ...
متن کاملResistance to flow of arterial Y-grafts 6 months after coronary artery bypass surgery.
BACKGROUND The use of both internal thoracic arteries (ITAs) as a Y-graft configuration has been proposed as a technique allowing complete arterial revascularization. Controversy remains, however, about the capacity of this Y-graft configuration to provide sufficient blood flow to the whole left coronary system and about possible steal phenomenon occurring during periods of maximal myocardial b...
متن کاملEarly postoperative flow rates after internal thoracic artery grafting for the left coronary artery system.
OBJECTIVE The low perioperative flow rates of internal thoracic artery (ITA) conduits have been regarded as a limitation of their use in critical coronary situations with a high myocardial blood demand. To clarify whether these restrictions are justified, early postoperative flow rates were determined. METHODS Following bilateral ITA grafting, 48 of 106 patients (April 1993-September 1994) un...
متن کاملThe impact of competitive flow on distal coronary flow and on graft flow during coronary artery bypass surgery.
To determine the impact of left anterior descending-competitive flow (LAD-CF) on distal coronary flow (LAD-DF) and on left internal mammary artery-graft flow (LIMA-GF), we performed a quantitative blood-flow analysis in a swine model of a LIMA-to-LAD coronary artery bypass graft (CABG). In six swine, a LIMA-to-LAD CABG was performed. LAD blood-flow was measured bilaterally to the LIMA-to-LAD an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2012 شماره
صفحات -
تاریخ انتشار 2012