3D MR cisternography to identify distal dural rings: comparison of 3D-CISS and 3D-SPACE sequences.

نویسندگان

  • Yoshiyuki Watanabe
  • Akari Makidono
  • Miho Nakamura
  • Yukihisa Saida
چکیده

PURPOSE The distal dural ring (DDR) is an anatomical landmark used to distinguish intra- and extradural aneurysms. We investigated identification of the DDR using 2 three-dimensional (3D) magnetic resonance (MR) cisternography sequences--3D constructive interference in steady state (CISS) and 3D sampling perfection with application optimized contrasts using different flip angle evolutions (SPACE)--at 3.0 tesla. METHODS Ten healthy adult volunteers underwent imaging with 3D-CISS, 3D-SPACE, and time-of-flight (TOF) MR angiography (TOF-MRA) sequences at 3.0T. We analyzed DDR identification and internal carotid artery (ICA) signal intensity and classified the shape of the carotid cave. RESULTS We identified the DDR using both 3D-SPACE and 3D-CISS, with no significant difference between the sequences. Visualization of the outline of the ICA in the cavernous sinus (CS) was significantly clearer with 3D-SPACE than 3D-CISS. In the CS and petrous portions, signal intensity was lower with 3D-SPACE, and the flow void was poor with 3D-CISS in some subjects. CONCLUSION We identified the DDR with both 3D-SPACE and 3D-CISS, but the superior contrast of the ICA in the CS using 3D-SPACE suggests the superiority of this sequence for evaluating the DDR.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MR cisternography of the cerebellopontine angle: comparison of three-dimensional fast asymmetrical spin-echo and three-dimensional constructive interference in the steady-state sequences.

BACKGROUND AND PURPOSE MR cisternography has been used as the noninvasive screening tool of the cerebellopontine angle. The purpose of this study was to directly compare two currently dominant types of sequences for heavily T2-weighted MR cisternography. METHODS Three-dimensional fast asymmetric spin-echo (3D-FASE) sequences, which are 3D half-Fourier rapid acquisition with relaxation enhance...

متن کامل

Identification of the distal dural ring with use of fusion images with 3D-MR cisternography and MR angiography: application to paraclinoid aneurysms.

BACKGROUND AND PURPOSE The distal dural ring (DDR) represents the anatomic border between the extradural and intradural internal carotid arteries (ICAs). The purpose of this study was to examine whether 3D-MR cisternography and MR angiography (MRA) fusion images can identify the boundary between the CSF and the cavernous sinus, which might represent the DDR. MATERIALS AND METHODS Thirty-six c...

متن کامل

Trigeminal ganglion and its divisions: detailed anatomic MR imaging with contrast-enhanced 3D constructive interference in the steady state sequences.

BACKGROUND AND PURPOSE Visualization of the trigeminal system is important for imaging diagnosis but technically challenging. We assessed how well the trigeminal ganglion, its rootlets, and its branches (V1, V2, and V3) are depicted on three high-resolution pulse sequences. METHODS Twenty-two patients (44 sides) underwent nonenhanced 3D constructive interference in the steady state (CISS) MR ...

متن کامل

Identification and anatomic description of the anterior choroidal artery by use of 3D-TOF source and 3D-CISS MR imaging.

BACKGROUND AND PURPOSE The importance of the anterior choroidal artery (AChA) is related to its supply of crucial anatomic structures, such as the internal capsule. Angiographically, the AChA can be detected in 71% to 98% of patients, but as yet, its visibility on MR images has not been evaluated. Our goal was to assess the sensitivity of MR imaging in the identification of the AChA and its ana...

متن کامل

Influence of perianeurysmal environment on the deformation and bleb formation of the unruptured cerebral aneurysm: assessment with fusion imaging of 3D MR cisternography and 3D MR angiography.

BACKGROUND AND PURPOSE Surface irregularity and bleb formation are anatomical factors that are associated with aneurysm rupture. The perianeurysmal environment has been proposed as one factor that may influence aneurysm morphology. We have developed a fusion imaging technique of 3D MR cisternography and angiography that allows clear visualization of an aneurysm and its environment. This techniq...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine

دوره 10 1  شماره 

صفحات  -

تاریخ انتشار 2011